Anatomy & Physiology › Section Q · The heart › Topic Q.2
Cardiac muscle and electrical activity
The heart starts every beat itself, without a signal from the brain. A small network of specialised muscle cells sets the rhythm and times the chambers, and an ECG lets us watch that electrical activity from the skin.
Muscle that excites itself
The topic Cardiac and smooth muscle described cardiomyocytes: short, branched, striated cells with one or two nuclei, joined end to end by intercalated discs. Desmosomes in those discs hold cells together under strain, and gap junctions let ions pass from cell to cell, so excitation spreads through the atria, and separately through the ventricles, as if each were one unit. About 99% of cardiomyocytes are contractile cells that do the pumping. The remaining 1% or so are conducting cells, which generate impulses and carry them rapidly through the heart. This property of generating its own rhythm is called autorhythmicity.
The conduction pathway
Each beat starts in the sinoatrial (SA) node, a cluster of conducting cells in the posterior wall of the right atrium near the opening of the superior vena cava. The impulse spreads through both atria, carried partly by internodal pathways, to the atrioventricular (AV) node in the lower interatrial septum. The cardiac skeleton blocks every other route to the ventricles. From the AV node the impulse runs down the AV bundle (bundle of His) into the interventricular septum, splits into the right and left bundle branches, travels to the apex and spreads through the ventricular walls in the Purkinje fibres.
Timing: the AV delay
The AV node's small cells pass the impulse slowly, holding it back for about 100 ms. That pause lets the atria finish contracting and topping up the ventricles before the ventricles fire. After the delay, conduction is fast: the bundle branches and Purkinje fibres excite the whole ventricular mass within roughly a tenth of a second. Because the Purkinje fibres reach the apex first, the ventricles contract from the apex upward, squeezing blood toward the aortic and pulmonary valves at the base. Branches in the moderator band reach the right papillary muscles early, so the chordae tighten just before the ventricle contracts.
Pacemaker potentials
Conducting cells have no stable resting potential. In an SA nodal cell, the membrane starts near −60 mV and drifts upward as Na⁺ leaks in through slow channels; this slow rise is the prepotential. At a threshold of about −40 mV, voltage-gated Ca²⁺ channels open and Ca²⁺ rushes in, producing the rapid upstroke. K⁺ channels then open, K⁺ leaves, and the cell repolarises, after which the drift starts again. The SA node reaches threshold fastest, so it sets the pace. Without nervous or hormonal input it would fire about 80 to 100 times a minute; the resting rate is usually lower because vagal input slows it.
Backup pacemakers
Every part of the conduction system can fire by itself, but the rate falls further down the pathway. If the SA node fails, the AV node typically takes over at about 40 to 60 beats per minute. If conduction through the AV node is blocked, the AV bundle or bundle branches may drive the ventricles at roughly 20 to 40 per minute, and the Purkinje fibres more slowly still. These slower escape rhythms keep blood moving, but often not well enough for normal activity. Clinicians may use an artificial pacemaker, a device that delivers small timed electrical impulses, when the heart's own system cannot keep an adequate rate.
The contractile cell action potential
A ventricular contractile cell rests at about −90 mV. When neighbouring cells excite it, fast Na⁺ channels open and the membrane shoots up to about +30 mV in a few milliseconds. Then comes the feature that makes heart muscle special: a long plateau, lasting about 175 ms, while slow Ca²⁺ channels let Ca²⁺ enter as K⁺ leaves, holding the voltage near zero. Finally the Ca²⁺ channels close and K⁺ outflow repolarises the cell. The entering Ca²⁺ triggers release of more Ca²⁺ from the sarcoplasmic reticulum, a process called calcium-induced calcium release, which drives the cross-bridge cycling familiar from skeletal muscle.
Why the heart cannot tetanise
The whole contractile action potential lasts about 250 to 300 ms, and the cell cannot be re-excited for most of it: its refractory period is roughly 250 ms, about as long as the contraction itself. A skeletal muscle fibre, with a refractory period of a few milliseconds, can be restimulated during a twitch and summed into a sustained tetanic contraction. Cardiac muscle cannot, so every contraction is followed by relaxation, and the chambers always get time to refill. Cardiomyocytes rely almost entirely on aerobic respiration, using fatty acids, glucose and lactate, and they are packed with mitochondria and myoglobin to match.
Reading the ECG
An electrocardiogram (ECG) records, from skin electrodes, the summed electrical activity of the heart. The P wave is atrial depolarisation. The QRS complex is ventricular depolarisation; atrial repolarisation happens at the same time and is hidden within it. The T wave is ventricular repolarisation. The PR interval, from the start of P to the start of QRS, covers atrial depolarisation plus the AV delay, typically about 0.12 to 0.20 s. A normal QRS complex is brief, usually under about 0.12 s, because Purkinje conduction is fast. On standard paper running at 25 mm/s, each 1 mm small square is 0.04 s.
Worked example: heart rate from an ECG
On a standard ECG at 25 mm/s, the peaks of consecutive R waves are 20 mm apart. What is the heart rate? 1. Convert distance to time: \(20\ \mathrm{mm} \div 25\ \mathrm{mm/s} = 0.8\) s per beat. 2. Beats per minute: \(60 \div 0.8 = 75\) beats per minute. 3. Shortcut: 20 mm is 20 small squares, and \(1500 \div 20 = 75\), since 1500 small squares pass each minute. 4. Check: 75 beats per minute lies within the usual adult resting range, so the answer is sensible.
Worked example: a strip with too many P waves
A typical textbook strip shows P waves every 0.75 s and QRS complexes every 1.5 s, with no fixed relationship between them. What is happening? 1. Atrial rate: \(60 \div 0.75 = 80\) per minute, a normal SA node rate. 2. Ventricular rate: \(60 \div 1.5 = 40\) per minute. 3. Because P waves and QRS complexes are unrelated, no impulses are crossing from atria to ventricles. 4. The ventricles must be driven by a backup pacemaker below the AV node. 5. Conclusion: this pattern fits complete (third-degree) heart block. This is a study exercise in reasoning, not a way to interpret anyone's real ECG.
Common mistakes to avoid
First, thinking the brain starts each heartbeat: nerves and hormones only speed it up or slow it down. Second, putting the AV node in the ventricle: it sits in the lower interatrial septum, in the right atrium. Third, saying the QRS complex shows ventricular contraction: it shows depolarisation, which comes just before contraction. Fourth, forgetting atrial repolarisation: it occurs but is hidden in the QRS. Fifth, crediting the plateau to Na⁺: it depends on slow Ca²⁺ entry balancing K⁺ exit.
Key takeaways
Conducting cells make the heart autorhythmic. The impulse runs SA node, atria, AV node (about 100 ms delay), AV bundle, bundle branches, Purkinje fibres, and the ventricles contract from the apex up. Pacemaker cells drift to threshold by slow Na⁺ entry and fire with Ca²⁺. Contractile cells show a fast Na⁺ upstroke, a long Ca²⁺ plateau and K⁺ repolarisation; the long refractory period prevents tetanus. On the ECG, P is atrial depolarisation, QRS ventricular depolarisation and T ventricular repolarisation; heart rate is 60 divided by the R-R interval in seconds.
Flashcards
Flashcard
The heart's ability to generate its own impulses
Test your understanding
Question 1 of 5
In which order does the impulse travel after leaving the SA node?
Question 2 of 5
Which ion movement produces the plateau of a ventricular contractile cell's action potential?
Question 3 of 5
On an ECG recorded at 25 mm/s, R waves are 15 small squares apart. What is the heart rate?
Question 4 of 5
Why can cardiac muscle not go into a sustained tetanic contraction?
Question 5 of 5
What does the T wave of a normal ECG represent?