Electrical Engineering › Section Z · AC motors › Topic Z.1
Introduction to motors and generators
Electric motors turn a large share of the world's electricity into motion, and generators make that electricity in the first place. They are the same kind of machine, and a few ideas about force, induction, torque and loss explain them all.
One machine, two directions
A motor takes in electrical energy, a voltage and a current, and delivers mechanical work at its shaft. A generator does the reverse: a turbine or engine turns its shaft and it delivers electrical energy. Inside, both have a stationary part, the stator, and a turning part, the rotor, separated by a narrow air gap and linked by a magnetic field. Because the physics runs both ways, most machines can work as either. The principles start with two effects you already know.
Motor action: force on a current
A straight conductor of length \(l\) carrying current \(I\) at right angles to a field of flux density \(B\) feels a force
perpendicular to both the wire and the field. A right-hand rule gives its direction: hold your right hand flat with the fingers along the field and the thumb along the conventional current, and the force pushes out of the palm. Put a rectangular loop in the field and the two sides that cross the flux are pushed in opposite directions, which gives a turning effect, a torque, \(T = Fr\) for each side at radius \(r\). A 0.15 m side carrying 5.0 A in 0.80 T feels 0.60 N.
Generator action and back EMF
From "Faraday's and Lenz's laws", a conductor moving across a field at speed \(v\) has a voltage \(e = Blv\) induced in it. So every motor is also a generator: as its rotor turns, its own conductors cut flux and develop a voltage. By Lenz's law that voltage opposes the current driving the motor, so it is called the back EMF. It is proportional to speed. At standstill there is none, which is why motors draw a large current when first switched on. As the motor speeds up, the back EMF rises and limits the current to what the load needs.
The brushed dc motor
The simplest motor to picture is the brushed dc motor. Its rotor, the armature, carries coils connected to a commutator, a ring of copper segments on the shaft. Fixed carbon brushes press on the segments and feed in the current. Every half turn the commutator reverses the current in each coil, so the torque keeps pointing the same way. Its speed rises with the supply voltage and its torque with the current. With armature resistance \(R_a\) and back EMF \(E_b\), Kirchhoff's voltage law gives
The brushes and commutator wear and spark, a weakness that shaped the history that follows.
Worked example: back EMF limits the current
A 24 V dc motor has an armature resistance of 0.50 Ω. 1. At the instant of starting the armature is still, so \(E_b = 0\) and \(I = 24/0.50 = 48\,\text{A}\). 2. At running speed the back EMF is 21 V, so \(I = (24 - 21)/0.50 = 6.0\,\text{A}\). 3. The power converted to mechanical form is \(E_bI = 21 \times 6.0 = 126\,\text{W}\); the rest of the input, \(I^2R_a = 18\,\text{W}\), heats the winding. 4. Check: \(24 \times 6.0 = 144\,\text{W} = 126 + 18\). A heavier load slows the motor, lowers \(E_b\) and raises the current automatically.
Why ac motors came later
Edison's first power systems of the early 1880s were dc. Alternating current soon proved cheaper for distribution, because transformers could step it up for long lines and down again for use, but motors were a problem. Early ac motors were built like dc motors, and their iron overheated in the constantly reversing field. Charles Steinmetz's work on hysteresis in the early 1890s let designers predict iron losses before building a machine. Meanwhile Nikola Tesla had taken a different route: a field that rotates by itself, dragging a simple rotor with it. His induction motor, patented in 1888, became the workhorse of industry.
Core losses: hysteresis and eddy currents
An ac field reverses many times a second, and iron pays for each reversal. Hysteresis loss, from "Reluctance, magnetizing force, and hysteresis", is proportional to the area of the B-H loop and to the frequency, so cores use soft magnetic steel with a narrow loop. Eddy currents are loops of current induced in the iron itself. To break them up, stator and rotor cores are stacks of thin laminations, insulated from one another; eddy loss falls roughly with the square of the lamination thickness. A few percent of silicon in the steel raises its resistivity, which cuts eddy currents further. Motors usually use non-oriented silicon steel, because their flux changes direction around the core.
Torque, speed, power and efficiency
Mechanical output power is
with \(T\) in newton metres and \(\omega\) in radians per second; nameplates give speed \(n\) in rpm, so use \(\omega = 2\pi n/60\). A gearbox trades torque for speed. In the US, output is often rated in horsepower, 1 hp = 746 W. Efficiency is \(\eta = P_{out}/P_{in}\). The losses, all ending as heat that ages the insulation, are copper loss (\(I^2R\) in the windings), core loss, friction and windage, and stray load losses. Motors use an estimated 40% or more of the world's electricity, according to the International Energy Agency, so the IEC efficiency classes, IE1 (standard) to IE4 (super premium) and beyond, set minimums that many countries require. Over its life a motor's electricity usually costs far more than the motor.
Worked example: power, efficiency and running cost
A motor delivers 25 N·m at 1,750 rpm. 1. \(\omega = 2\pi \times 1750/60 = 183.3\,\text{rad/s}\). 2. \(P = 25 \times 183.3 = 4.58\,\text{kW}\), about 6.14 hp. 3. At 90.0% efficiency the input is \(4.58/0.900 = 5.09\,\text{kW}\), so 509 W is lost as heat. 4. A 93.0% motor needs 4.93 kW for the same output. 5. Running 6,000 hours a year at $0.12 per kWh, the 90% motor uses 30,500 kWh, costing about $3,670, and the better motor saves about 985 kWh, roughly $118 a year. Rounded to three figures.
A map of ac motors
The machines in the rest of this part fall into a few families. Synchronous machines turn exactly in step with the supply frequency; the next topic, "Synchronous motors, synchronous condensers, and reluctance motors", covers them, and "Stepper motors and brushless DC motors" covers their electronically driven cousins. Asynchronous, or induction, machines turn slightly slower than their field and are described in "Polyphase, wound-rotor, and single-phase induction motors". Shaded-pole, hysteresis and servo motors, synchros, and brushed ac machines such as the universal motor appear in "Specialized, synchro, and AC commutator motors". The electronics that drive them belong to "Pulse-width modulation, DC motor drives, inverters, and AC motor drives".
Common mistakes to avoid
First, using rpm directly in \(P = T\omega\); convert to rad/s with \(2\pi n/60\). Second, forgetting back EMF and computing a running motor's current as \(V/R_a\), which is only the starting current. Third, thinking laminations reduce hysteresis loss; they reduce eddy currents, while hysteresis depends on the steel. Fourth, inverting efficiency: output over input is always below 100%. Fifth, treating motors and generators as different devices; the same machine does either job, depending on which way energy flows.
Key takeaways
Motors and generators are the same machines run in opposite directions. Motor action is the force F = BIl on a current in a field; generator action is the induced voltage e = Blv. A turning motor generates a back EMF, proportional to speed, that limits its current: V = E_b + IR_a for a dc motor. AC machines suffer hysteresis and eddy-current losses, reduced by soft silicon steel and thin laminations. Mechanical power is P = Tω with ω = 2πn/60. Efficiency is output over input; losses are copper, core, friction and windage, and stray. Motors use an estimated 40% or more of world electricity.
Flashcards
Flashcard
Converts electrical energy into mechanical work
Test your understanding
Question 1 of 5
A 12 V brushed dc motor has an armature resistance of 0.40 Ω. Running at speed, its back EMF is 10.8 V. What armature current does it draw?
Question 2 of 5
A motor delivers 40 N·m of torque at 1,500 rpm. What mechanical power does it deliver?
Question 3 of 5
A motor takes 8.2 kW from the supply and delivers 7.5 kW at its shaft. What is its efficiency?
Question 4 of 5
Why are the stator and rotor cores of an ac motor built from thin, insulated laminations?
Question 5 of 5
A dc motor running at steady speed is given a heavier load, and it slows down. What happens to its back EMF and its armature current?