Electrical Engineering › Section Z · AC motors › Topic Z.5
Specialized, synchro, and AC commutator motors
Beyond the big families of synchronous and induction motors lie machines built for one job: the cheap fan motor, the low-inertia servo, the silent clock drive, the synchro that sends an angle down a wire, and the universal motor screaming inside a drill.
Motors for particular jobs
The machines in this topic borrow the principles of the earlier ones. Shaded-pole, servo and hysteresis motors are variations on the induction motor of "Polyphase, wound-rotor, and single-phase induction motors". Synchros and resolvers are rotary transformers that carry information about a shaft angle rather than power. AC commutator motors, the universal motor above all, are brushed dc motors adapted to run on ac, the problem that occupied early designers such as Steinmetz. Each wins a niche on cost, speed, smoothness or precision.
The shaded-pole motor
The cheapest way to start a single-phase motor is to wrap a shorted copper band, the shading coil, round about a third of each stator pole. As the pole's flux changes, the band carries an induced current that, by Lenz's law, delays the flux in the shaded part. The flux therefore peaks first in the unshaded part and then in the shaded part, a crude field that sweeps across the pole and drags a squirrel-cage rotor towards the shaded side. Starting torque and efficiency are low, so shaded-pole motors are made only in small sizes, typically below about 50 W, for small fans.
The two-phase ac servo motor
A servo motor positions something within a feedback loop, so it must respond fast. The ac servo has two stator windings 90° apart. The reference winding runs from the line through a capacitor, which shifts its current by roughly 90°; the control winding is fed by an amplifier. The amplitude of the control voltage sets the torque, and inverting its phase by 180° reverses the motor; with no control signal it stops. To cut inertia the rotor is often a thin aluminium drag cup, with fixed iron inside it to complete the magnetic path. Aircraft systems commonly run such servos at 400 Hz, which makes their magnetic parts smaller and lighter.
Hysteresis motors and eddy-current drives
Replace the cage rotor with a smooth cylinder of hard magnetic steel and the rotor's magnetisation lags the rotating field because of hysteresis, the effect described in "Reluctance, magnetizing force, and hysteresis". That lag produces a nearly constant torque from standstill right up to synchronous speed, where the rotor locks into step as a permanent magnet. The result is a small, quiet, self-starting synchronous motor, once used in clocks and record turntables. In an eddy-current drive, or clutch, a dc-excited member on the load shaft faces a conducting drum turned by a constant-speed motor, and the dc field current smoothly sets the torque passed between them.
Synchros: sending an angle down a wire
A synchro, or selsyn (self-synchronous), has a rotor winding excited by ac through slip rings and three stator windings 120° apart. It is a rotary transformer: each stator winding picks up a voltage in phase with the excitation, or inverted, with an amplitude proportional to the cosine of the angle between rotor and that winding. Connect the stators of a torque transmitter (TX) and a torque receiver (RX) together and excite both rotors from the same supply. If their rotors sit at the same angle the stator voltages balance and no current flows; turn the TX shaft and currents flow until the RX rotor follows.
Worked example: synchro stator voltages
A synchro's three stator windings lie at 0°, 120° and 240°, and with the rotor at 0° the 0° winding has its maximum voltage, 10.0 V. Find each winding's voltage, measured from the star point, with the rotor at 30°. 1. Winding at 0°: \(10.0\cos(30^\circ - 0^\circ) = 8.66\,\text{V}\), in phase with the excitation. 2. Winding at 120°: \(10.0\cos(-90^\circ) = 0\). 3. Winding at 240°: \(10.0\cos(-210^\circ) = -8.66\,\text{V}\), meaning 8.66 V in antiphase. 4. Each rotor angle gives a different set, so the set encodes the angle; a receiver whose rotor reaches 30° matches it, and the current stops.
Differential synchros and control transformers
A torque differential transmitter (TDX) has three-phase windings on both rotor and stator. Placed between a TX and an RX, it adds its own shaft angle to the electrical angle it receives, or subtracts it if two leads are swapped. A control transformer (CT) is a synchro used as a detector: its rotor gives zero output when it sits at 90° to the stator field, and otherwise an error voltage proportional to the sine of the angle error, its phase showing which way. In a servo loop, a TX sets the commanded angle, a CT on the load measures the actual angle, and an amplifier drives a servo motor until the CT output is a null.
Worked example: a ship's radar display
A ship heads 30° east of true north, and its radar antenna points 15° to starboard of the bow. 1. The antenna's TX sends 15°. 2. A TDX turned by the gyrocompass adds the heading: \(15^\circ + 30^\circ = 45^\circ\), and the display's RX shows the antenna's true bearing, 45°. 3. Now let a servo point a searchlight to a commanded 40°, using a CT whose maximum output is 20 V. 4. With the light at 25°, the error is \(20\sin(40^\circ - 25^\circ) = 5.18\,\text{V}\). 5. Overshooting to 55° gives \(20\sin(-15^\circ)\): 5.18 V in antiphase, so the amplifier reverses the motor.
The resolver
A resolver has a single excited rotor winding and two stator windings at 90°. With rotor angle \(\theta\) and excitation amplitude \(V\), the stator outputs are \(V\cos\theta\) and \(V\sin\theta\), so the device converts polar coordinates into rectangular ones. Feed it 8.0 V standing for a target's range and turn it to the bearing, 35°: the outputs are \(8.0\cos 35^\circ = 6.55\,\text{V}\) and \(8.0\sin 35^\circ = 4.59\,\text{V}\), the target's x and y. With no electronics inside, a resolver tolerates heat and vibration, so it is widely used as the rotor position sensor of brushless motors in servo drives and electric vehicles.
AC commutator and universal motors
A dc series motor will run on ac, because its field and armature currents reverse together, so the torque, proportional to the square of the current, keeps its direction while pulsing at twice the line frequency. Practical ac versions need a laminated field to limit eddy currents, few field turns to limit reactance, and, in all but small sizes, a compensating winding that cancels the armature's mmf and reduces sparking at the brushes. The universal motor, a small series motor for ac or dc, often exceeds 10,000 rpm, giving high power for its weight in drills, vacuum cleaners and mixers, but its speed falls sharply with load. The repulsion motor, now rare, feeds only its stator and shorts offset brushes on the armature, giving high starting torque.
Common mistakes to avoid
First, thinking a synchro transmits power to drive heavy loads; it transmits an angle, with only light torque. Second, reading a control transformer's null as its rotor lined up with the stator field; the null is at 90° to it. Third, believing a series motor on ac reverses each half cycle; field and armature reverse together, so torque keeps its direction. Fourth, expecting a universal motor to hold a steady speed; it slows markedly under load. Fifth, trying to reverse a shaded-pole motor by swapping its leads; its direction is set by where the shading coils sit.
Key takeaways
Shaded-pole motors start from shading coils that delay part of each pole's flux. AC servo motors pair a reference winding with an amplifier-fed control winding. Hysteresis motors give constant torque up to synchronous speed. Synchros are rotary transformers: TX and RX transmit an angle, a TDX adds or subtracts angles, and a CT gives an error voltage proportional to the sine of the angle error. A resolver outputs V cos θ and V sin θ. Series ac and universal motors run because field and armature reverse together.
Flashcards
Flashcard
Shorted copper band round part of a pole that delays its flux
Test your understanding
Question 1 of 5
A synchro's rotor is at 90°. Its stator windings lie at 0°, 120° and 240°, and the largest possible winding voltage is 10 V. What is the voltage of the winding at 0°?
Question 2 of 5
A control transformer has a maximum output of 20 V. The commanded angle is 50° and the load sits at 40°. What error voltage does it produce?
Question 3 of 5
A resolver's rotor is excited at 12 V and its shaft is turned to 60°. What are its two stator outputs?
Question 4 of 5
Why does a dc series motor keep turning the same way when it is connected to an ac supply?
Question 5 of 5
What gives a shaded-pole motor its starting torque?