Electrical Engineering › Section O · Pulses, nonsinusoidal signals, and system analysis › Topic O.5
Two-port parameters: z, y, and h
Any linear two-port, from a resistor network to a transistor at small signals, can be captured by four parameters that link its port voltages and currents. Three standard sets, z, y and h, each suit different devices and measurements, and they convert into one another.
Four numbers for any linear two-port
The previous topic, Input and output impedance, gains, and cascaded systems, described amplifiers by a few measured quantities. Two-port parameters go further: they model any linear network with an input port and an output port exactly, at a given frequency, without knowing what is inside. The convention is fixed. Port 1 has voltage \(V_1\) and current \(I_1\); port 2 has \(V_2\) and \(I_2\). Both currents are taken as entering the + terminal of their port, the passive sign convention. In general these are phasors and the parameters are complex; this topic's examples are resistive, so real values serve. Two of the four quantities are chosen as independent variables, and two equations give the other two. Which pair is chosen decides the parameter set.
Impedance (z) parameters
Taking the currents as independent gives
Each parameter is found by leaving one port open, so these are the open-circuit impedance parameters, all in ohms. With port 2 open (\(I_2 = 0\)): \(z_{11} = V_1/I_1\), the input impedance, and \(z_{21} = V_2/I_1\), the forward transfer impedance. With port 1 open (\(I_1 = 0\)): \(z_{22} = V_2/I_2\), the output impedance, and \(z_{12} = V_1/I_2\), the reverse transfer impedance. A network of passive R, L and C elements is reciprocal, so \(z_{12} = z_{21}\).
Worked example: z parameters of a T network
A T network has \(R_1\) = 2 kΩ from port 1's top terminal to a centre node, \(R_2\) = 3 kΩ from the centre node to port 2's top terminal, and \(R_3\) = 6 kΩ from the centre node to the common bottom line. 1. Port 2 open: current \(I_1\) flows through \(R_1\) and \(R_3\) only, so \(z_{11} = 2 + 6 = 8\,\text{k}\Omega\). 2. With port 2 still open, \(V_2\) equals the voltage across \(R_3\), since no current flows in \(R_2\): \(z_{21} = 6\,\text{k}\Omega\). 3. Port 1 open: \(z_{22} = 3 + 6 = 9\,\text{k}\Omega\), and \(z_{12} = 6\,\text{k}\Omega\). 4. Check: \(z_{12} = z_{21}\), as a passive network requires.
Using the z model with a load
The z equations correspond to an equivalent circuit: at port 1, \(z_{11}\) in series with a current-controlled voltage source \(z_{12}I_2\); at port 2, \(z_{22}\) in series with a source \(z_{21}I_1\). To find the input impedance with a load \(R_L\) on port 2, note that \(V_2 = -I_2R_L\), because \(I_2\) is defined as entering the port. Substituting gives
For the T network with \(R_L\) = 3 kΩ: \(Z_i = 8 - \frac{(6)(6)}{9 + 3} = 5\,\text{k}\Omega\). Check directly: \(R_1 + R_3 \parallel (R_2 + R_L) = 2 + (6 \parallel 6) = 5\,\text{k}\Omega\).
Admittance (y) parameters
Taking the voltages as independent gives
Now each parameter is found with one port short-circuited, so these are the short-circuit admittance parameters, in siemens. With port 2 shorted (\(V_2 = 0\)): \(y_{11} = I_1/V_1\) and \(y_{21} = I_2/V_1\). With port 1 shorted (\(V_1 = 0\)): \(y_{22} = I_2/V_2\) and \(y_{12} = I_1/V_2\). The equivalent circuit has an admittance \(y_{11}\) in parallel with a voltage-controlled current source \(y_{12}V_2\) at port 1, and likewise at port 2. Reciprocal networks have \(y_{12} = y_{21}\). The y set suits π networks and devices measured with shorted ports.
Worked example: y parameters of the T network
Use the same T network (2 kΩ, 3 kΩ, 6 kΩ). 1. Short port 2: the input sees \(R_1 + R_3 \parallel R_2 = 2 + 2 = 4\,\text{k}\Omega\), so \(y_{11} = 1/4\,\text{k}\Omega = 0.250\,\text{mS}\). 2. The current divider sends \(\frac{6}{6 + 3} = \frac{2}{3}\) of \(I_1\) through the short, flowing out of port 2, so \(I_2 = -\frac{2}{3}I_1\) and \(y_{21} = -\frac{2}{3}(0.250) = -0.167\,\text{mS}\). 3. Short port 1: the output sees \(3 + (2 \parallel 6) = 4.5\,\text{k}\Omega\), so \(y_{22} = 0.222\,\text{mS}\), and by reciprocity \(y_{12} = -0.167\,\text{mS}\). 4. Check: the y matrix should be the inverse of the z matrix, as the conversion card shows.
Hybrid (h) parameters
The hybrid set takes \(I_1\) and \(V_2\) as independent:
With port 2 shorted: \(h_{11} = V_1/I_1\), an input impedance in ohms, and \(h_{21} = I_2/I_1\), a forward current gain. With port 1 open: \(h_{12} = V_1/V_2\), a reverse voltage ratio, and \(h_{22} = I_2/V_2\), an output admittance in siemens. The mixed units give the name. The equivalent circuit is \(h_{11}\) in series with a voltage source \(h_{12}V_2\) at the input, and a current source \(h_{21}I_1\) in parallel with \(1/h_{22}\) at the output. Bipolar transistor data sheets list them for the common-emitter connection as \(h_{ie}\), \(h_{re}\), \(h_{fe}\) and \(h_{oe}\); \(h_{fe}\) is the small-signal current gain.
Worked example: a transistor's input and output impedance
A transistor has \(h_{ie}\) = 2.0 kΩ, \(h_{re}\) = 2.5 × 10⁻⁴, \(h_{fe}\) = 120 and \(h_{oe}\) = 20 µS, with \(R_L\) = 4.7 kΩ and a source resistance \(R_s\) = 1.0 kΩ. 1. Input impedance:
2. Output impedance:
3. Voltage gain, solved from the h equations with \(V_2 = -I_2R_L\), where \(\Delta_h = h_{11}h_{22} - h_{12}h_{21}\):
4. Check: ignoring \(h_{re}\) and \(h_{oe}\) gives \(Z_i \approx 2.0\,\text{k}\Omega\) and \(A_v \approx -h_{fe}R_L/h_{ie} = -282\), close, which is why simple models often drop them.
Converting between parameter sets
Because the z and y equations solve for opposite variables, the y matrix is the inverse of the z matrix. With \(\Delta_z = z_{11}z_{22} - z_{12}z_{21}\):
and the h set follows from z as
For the T network, \(\Delta_z = (8)(9) - (6)(6) = 36\) (kΩ)², giving \(y_{11} = 9/36 = 0.250\) mS and \(y_{12} = -0.167\) mS, as found directly, and \(h_{11} = 4\,\text{k}\Omega\), \(h_{12} = 0.667\), \(h_{21} = -0.667\) and \(h_{22} = 0.111\) mS.
Common mistakes to avoid
First, using the wrong termination: z parameters need an open port, y parameters a shorted port, and h parameters one of each (port 2 shorted for \(h_{11}\) and \(h_{21}\), port 1 open for \(h_{12}\) and \(h_{22}\)). Second, flipping the sign of \(I_2\): it enters port 2, so a load gives \(V_2 = -I_2R_L\), and \(y_{21}\) of a resistive T network comes out negative. Third, writing \(h_{12}\) or \(h_{21}\) with units: both are ratios. Fourth, inverting each z parameter separately to get y: \(y_{11}\) is \(z_{22}/\Delta_z\), not \(1/z_{11}\). Fifth, expecting \(z_{12} = z_{21}\) for a transistor: active devices are not reciprocal.
Key takeaways
A linear two-port has port variables V₁, I₁, V₂, I₂, with both currents entering. z parameters, V = zI, are open-circuit impedances in ohms. y parameters, I = yV, are short-circuit admittances in siemens, and the y matrix is the inverse of the z matrix. h parameters take I₁ and V₂ as independent: h₁₁ in ohms and h₂₁ (a current gain) with port 2 shorted, h₁₂ (a voltage ratio) and h₂₂ in siemens with port 1 open; transistor data use h_ie, h_re, h_fe, h_oe. Passive networks are reciprocal (z₁₂ = z₂₁, y₁₂ = y₂₁). With a load, V₂ = −I₂R_L gives formulas for Z_i, Z_o and gain.
Flashcards
Flashcard
V₁, I₁ at port 1 and V₂, I₂ at port 2, both currents entering
Test your understanding
Question 1 of 5
A T network has 1 kΩ from port 1's top terminal to the centre node, 4 kΩ from the centre node to port 2's top terminal, and 5 kΩ from the centre node to the common line. What are z₁₁ and z₂₁?
Question 2 of 5
Which condition is used to measure y parameters, and what are their units?
Question 3 of 5
A two-port has z₁₁ = 10 kΩ, z₁₂ = z₂₁ = 4 kΩ and z₂₂ = 6 kΩ. What is y₁₁?
Question 4 of 5
For a common-emitter transistor, which h parameter is the small-signal forward current gain, measured with the output shorted?
Question 5 of 5