Electrical Engineering › Section A · Introduction, current, and voltage › Topic A.5
Ammeters and voltmeters
Current and voltage are invisible, so every circuit you build, repair or test depends on meters. Connecting them the right way round, in the right place and on the right range is the first practical skill of electrical work.
Two quantities, two connections
Current and voltage are different kinds of quantity, so they are measured differently. Current is a flow through an element, so an ammeter must be placed in the path of that flow: it is connected in series, and the circuit has to be opened to insert it. Voltage is a difference between two points, so a voltmeter is connected in parallel, its two leads touching the two points while the circuit stays intact. Most work today is done with a digital multimeter (DMM), which measures current, voltage and resistance on one instrument, but the connection rules are the same for any meter.
The ammeter
To measure current, switch off, open the circuit at the point of interest, and bridge the gap with the ammeter so that all the current passes through it. An ideal ammeter drops no voltage across itself, so inserting it does not change the current it measures. Real ammeters come close; the effect of their small internal voltage drop is examined in "Measurement techniques". On a DMM, current uses separate input jacks, typically one marked A for currents up to about 10 A and one marked mA or µA for small currents, each protected by an internal fuse. The common jack, COM, takes the black lead for every measurement.
The voltmeter
To measure voltage, touch the two leads to the two points whose difference you want; nothing in the circuit needs to be disconnected. An ideal voltmeter draws no current, so it does not disturb the circuit. A DMM reads the voltage of the red lead relative to the black lead, so it displays \(V_{ab}\) when the red lead is on point \(a\) and the black on point \(b\). With the black lead on ground, node 0, the meter reads the single-subscript voltage of the point under the red lead. How much a real voltmeter disturbs a high-resistance circuit is the subject of "Voltmeter loading effects".
Polarity and the meaning of a minus sign
A DMM shows a positive current when conventional current enters through the red lead and leaves through COM, and a positive voltage when the red lead is at the higher potential. Connected the other way round, it simply shows a minus sign; the magnitude is still correct, and the sign tells you the actual direction or polarity. The sign is information, not an error. Most analogue needle meters cannot show negative values: reversed, the needle slams against its zero stop, so their polarity must be right before connecting.
Worked example: measuring a torch circuit
A torch has a 3.0 V battery, a switch and a lamp in series: the battery's positive terminal goes to the switch, the switch to one lamp terminal, call it \(a\), and the lamp's other terminal, \(b\), back to the battery's negative terminal. 1. Current: switch off, disconnect the wire between the switch and \(a\), put the red lead (in the A jack) on the switch side and the black lead on \(a\). 2. Switch on: conventional current leaves the battery's positive terminal and enters the red lead, so the reading is positive. 3. Voltage: restore the wire, move the red lead to the V jack, then place red on \(a\) and black on \(b\); the meter reads \(V_{ab}\), positive because \(a\) is nearer the positive terminal.
Ranges, resolution and counts
A meter's range is the largest value it can display at a setting. Autoranging DMMs choose for you; on a manual-range meter, start on the highest range and step down until the reading is as large as possible without overflowing, because a lower range shows more digits. A DMM's resolution is set by its counts: a 6000-count meter displays up to 5999, so on its 6 V range the smallest step is 0.001 V and on its 60 V range it is 0.01 V. A voltage that reads 4.986 V on the 6 V range would show only 5.0 on the 600 V range, losing two digits of detail.
Accuracy specifications
Resolution is not accuracy: a meter showing 0.001 V steps may be off by more than that. Manufacturers state DC accuracy in the form \(\pm(\text{percentage of reading} + \text{counts})\), where one count is one step in the last digit on the range in use. To find the uncertainty, take the percentage of the displayed reading, then add the counts converted into units of that range. The true value lies within the reading plus or minus that amount, provided the meter is within its calibration period and used in the conditions the manufacturer states.
Worked example: how good is the reading?
A 6000-count DMM on its 6 V range reads 4.986 V. Its specification is \(\pm(0.5\% + 2\ \text{counts})\). 1. Percentage part: \(0.005 \times 4.986 = 0.0249\) V. 2. Counts part: on the 6 V range one count is 0.001 V, so 2 counts is 0.002 V. 3. Total uncertainty: \(0.0249 + 0.002 = 0.0269\) V, about \(\pm 0.027\) V. 4. Range of the true value: \(4.986 \pm 0.027\), from 4.959 V to 5.013 V. 5. Check: a nominal 5.0 V supply reading 4.986 V is within specification, and the last displayed digit, 6, cannot be trusted by itself.
Worked example: choosing a current range
A manual-range 6000-count meter has current ranges of 600 µA, 60 mA, 600 mA and 10 A. A motor is expected to draw about 0.35 A. 1. Convert: 0.35 A is 350 mA. 2. Ranges below 350 mA would overflow, so 600 µA and 60 mA are out. 3. Of the ranges that fit, 600 mA gives the finest resolution, 0.1 mA, against 0.01 A on the 10 A range. 4. With the leads in the mA jack the display shows −352.4 mA. 5. Interpret: the magnitude is 352.4 mA, and the minus sign means conventional current is entering through COM, so the leads are reversed relative to the assumed direction.
Using meters safely
Never connect a meter set to measure current across a voltage source or across a component. Its current input is close to a short circuit, so it will draw a large current, blowing the fuse at best and damaging the meter or the source at worst. After a current measurement, move the red lead back to the V jack before measuring voltage. Before using a meter near mains equipment, check its measurement category (CAT) rating, defined in IEC safety standards, and its leads. Mains measurements are for trained people, with equipment isolated wherever possible: never work on live mains.
Common mistakes to avoid
First, connecting an ammeter in parallel, which shorts the element and can blow the meter's fuse. Second, connecting a voltmeter in series, which almost stops the current and gives a misleading reading. Third, forgetting to move the red lead out of the A jack after measuring current. Fourth, treating a minus sign on a DMM as a fault rather than a direction. Fifth, reading on a range far larger than needed and losing resolution. Sixth, confusing resolution with accuracy: always check the specification.
Key takeaways
Ammeters go in series, so the circuit must be opened; ideally they drop no voltage. Voltmeters go in parallel across the two points; ideally they draw no current. A DMM reads red relative to black, and a minus sign shows reversed direction or polarity. Choose the smallest range that holds the reading for the best resolution. Accuracy is quoted as ±(percentage of reading + counts), with counts measured in the last digit of the range. Never put a meter set for current across a source, and never work on live mains.
Flashcards
Flashcard
In series: open the circuit and pass all the current through the meter
Test your understanding
Question 1 of 5
To measure the current through a resistor in a working circuit, how should the ammeter be connected?
Question 2 of 5
A DMM measuring a circuit's current reads −0.250 A. What does this mean?
Question 3 of 5
A meter on its 60.00 V range reads 12.00 V. Its accuracy is ±(0.5% + 3 counts). What is the uncertainty?
Question 4 of 5
A 6000-count manual-range meter has ranges of 600 mV, 6 V, 60 V and 600 V. Which range gives the best resolution for a reading of about 4.2 V?
Question 5 of 5
Ideally, how should a voltmeter and an ammeter affect the circuits they measure?