Electrical Engineering › Section C · Series circuits › Topic C.4
Internal resistance and voltage regulation
Connect a heavy load to a real battery or supply and its terminal voltage sags. Modelling the source as an ideal voltage with a small resistance inside explains the sag, predicts it, and gives a single figure, voltage regulation, for how close a supply comes to ideal.
Real sources sag
So far every source has been ideal: it holds the same voltage whatever current is drawn. Real generators, batteries and laboratory supplies do not. Turn on a car's headlights and then crank the engine, and the lights dim for a moment. The battery has not changed its chemistry in that instant. What has changed is the current, and part of the battery's voltage is now being used up inside the battery itself. To analyse this, we need a model of a real source that still uses only the ideas taught so far: sources, resistors and Kirchhoff's voltage law.
The model of a real source
Every real voltage source can be modelled as an ideal source \(E\) in series with an internal resistance \(R_{int}\). With nothing connected, no current flows, so there is no drop across \(R_{int}\) and the terminals show the full source voltage. This no-load voltage is \(V_{NL} = E\), and it is what a voltmeter reads across an unloaded battery. An ideal source is simply the special case \(R_{int} = 0\). The internal resistance is not a separate part you could unsolder; it lumps together the resistance of the electrodes, electrolyte, windings or output circuitry into one equivalent value.
Terminal voltage under load
Connect a load \(R_L\). Now \(E\), \(R_{int}\) and \(R_L\) form one series loop, so the load current is \(I_L = E/(R_{int} + R_L)\). KVL around the loop gives \(E - I_LR_{int} - V_L = 0\), so the terminal voltage is
The more current the load draws, the larger the internal drop and the lower the terminal voltage. Rearranging gives two ways to find the internal resistance from measurements:
Worked example: finding R_int
An unregulated dc adaptor reads 24.0 V with no load. With a 47 Ω resistor across its terminals, the terminal voltage falls to 23.2 V. Find its internal resistance. 1. Load current: \(I_L = 23.2\,\text{V}/47\,\Omega = 0.494\,\text{A}\). 2. Internal drop: \(24.0 - 23.2 = 0.8\,\text{V}\). 3. Internal resistance: \(R_{int} = 0.8/0.494 = 1.62\,\Omega\). 4. Check by the second form: \(24.0/0.494 - 47 = 1.62\,\Omega\). 5. The missing 0.8 V has not vanished; it appears across \(R_{int}\), which turns about 0.39 W into heat inside the adaptor.
The voltage-current line
Plot terminal voltage against load current and the model gives a straight line. It starts at \(V_{NL}\) when \(I_L = 0\) and falls with slope \(-R_{int}\), so a source with larger internal resistance has a steeper line. For any interval on the line, \(R_{int} = \Delta V_L / \Delta I_L\): if the voltage falls 0.6 V while the current rises 1.5 A, \(R_{int} = 0.4\,\Omega\). In principle the line would reach 0 V at \(I_L = V_{NL}/R_{int}\), the current with the terminals shorted, but a battery or supply should not be tested that way, because that current can destroy the source or the meter.
Power lost inside the source
Multiply \(V_L = V_{NL} - I_LR_{int}\) by \(I_L\) and you get a power balance:
The load receives the power the ideal source produces minus \(I_L^2R_{int}\), which is dissipated as heat inside the source. Because this loss grows with the square of the current, it matters most for heavy loads. A car battery reading 12.7 V at rest that falls to 10.9 V while delivering 180 A to a starter motor has \(R_{int} = 1.8/180 = 0.01\,\Omega\), yet it wastes \(180^2 \times 0.01 = 324\,\text{W}\) internally. Internal resistance typically rises as a battery ages, discharges or gets cold.
Worked example: a battery with known R_int
A 6.0 V battery with \(R_{int} = 0.50\,\Omega\) drives a 10 Ω load. Find the terminal voltage and the power lost inside. 1. Current: \(I_L = 6.0/(0.50 + 10) = 0.571\,\text{A}\). 2. Terminal voltage: \(V_L = 6.0 - (0.571)(0.50) = 5.71\,\text{V}\), which also equals \((0.571)(10)\). 3. Internal loss: \(P = I_L^2R_{int} = 0.163\,\text{W}\). 4. Load power: \(I_L^2R_L = 3.27\,\text{W}\). 5. Check: the ideal source produces \(6.0 \times 0.571 = 3.43\,\text{W}\), which equals \(3.27 + 0.163\). Treating the source as ideal would have overstated the load voltage by about 0.29 V.
Voltage regulation
Ideally a supply set to 12 V keeps 12 V across its terminals whatever the load demands. Voltage regulation (VR) measures how close a supply comes to that, comparing the no-load voltage with the full-load voltage \(V_{FL}\), the terminal voltage at the largest rated current:
An ideal supply has \(V_{FL} = V_{NL}\) and a regulation of 0%. The smaller the percentage, the less the output moves as the load changes. Note that the full-load voltage, not the no-load voltage, goes in the denominator.
Regulation and internal resistance
At full load, \(V_{NL} - V_{FL} = I_{FL}R_{int}\) and \(V_{FL} = I_{FL}R_L\), where \(R_L\) is the full-load resistance. Dividing one by the other cancels the current:
So for the same load, a smaller internal resistance gives better regulation. This is why a supply meant for large currents must have a very small internal resistance. Many modern bench supplies use feedback circuits that hold the output almost constant up to a set current limit, which makes them behave nearly ideally inside that range.
Worked example: a 5 V supply
A 5 V supply reads 5.00 V with no load and 4.85 V at its full rated current of 2.0 A. 1. Regulation: \(\text{VR} = (5.00 - 4.85)/4.85 \times 100\% = 3.09\%\). 2. Internal resistance: \(R_{int} = 0.15\,\text{V}/2.0\,\text{A} = 0.075\,\Omega\). 3. Full-load resistance: \(R_L = 4.85/2.0 = 2.425\,\Omega\). 4. Check by the second formula: \(0.075/2.425 \times 100\% = 3.09\%\). Both routes agree, as they must, because they describe the same series loop.
Common mistakes to avoid
First, expecting a battery's resting voltage under load; any current lowers the terminal voltage by \(I_LR_{int}\). Second, dividing by \(V_{NL}\) instead of \(V_{FL}\) in the regulation formula, which gives a slightly smaller, wrong percentage. Third, using \(I = E/R_L\) for the load current, which forgets that \(R_{int}\) is in series with the load. Fourth, trying to measure internal resistance with an ohmmeter across a live source or by shorting it with an ammeter; Measurement techniques covers the safe method.
Key takeaways
A real source is an ideal source E in series with R_int. With no load, V_NL = E; with a load, V_L = V_NL − I_L R_int and I_L = E/(R_int + R_L). R_int = (V_NL − V_L)/I_L, and it equals the slope of the V–I line. The source wastes I_L² R_int as heat. Voltage regulation, VR = (V_NL − V_FL)/V_FL × 100% = R_int/R_L × 100%, is 0% for an ideal supply; smaller is better.
Flashcards
Flashcard
Ideal source E in series with internal resistance R_int
Test your understanding
Question 1 of 5
A battery reads 9.0 V with no load. When it supplies 0.30 A, its terminal voltage is 8.4 V. What is its internal resistance?
Question 2 of 5
A 12 V source with 0.5 Ω internal resistance drives a 5.5 Ω load. What is the terminal voltage?
Question 3 of 5
A supply gives 15.0 V with no load and 14.4 V at full load. What is its voltage regulation?
Question 4 of 5
Two supplies have the same no-load voltage and drive the same load. Supply X has the smaller internal resistance. Which statement is true?
Question 5 of 5
A 12.6 V car battery with an internal resistance of 0.012 Ω delivers 150 A to a starter motor. How much power is turned into heat inside the battery?