Electrical Engineering › Section C · Series circuits › Topic C.5

Measurement techniques

A meter only tells the truth if it is connected the right way round, in the right place, and without disturbing what it measures. This topic turns series-circuit theory into bench practice, from reading signed voltages to measuring a source's internal resistance safely and finding a fault in a dead string.

Meters in series circuits

The topic Ammeters and voltmeters introduced the two instruments. Series circuits now explain the placement rules. An ammeter measures the current through itself, so it must be placed in series with the branch whose current you want, which means opening the circuit and inserting the meter into the gap. A voltmeter measures the potential difference between its two leads, so it is connected across the element, with the circuit left intact. In a single series loop the current is the same everywhere, so an ammeter inserted at any point in the loop gives the same reading.

Ammeter resistance and burden

An inserted ammeter adds its own resistance \(R_m\) to the loop, so it slightly lowers the current it is trying to measure. Ideally \(R_m = 0\). In practice the effect is negligible when \(R_m\) is tiny compared with the other resistance in the branch, but once it approaches about 10% of that resistance the error is significant. For example, 5 V across 100 Ω gives 50 mA, but with a 10 Ω meter in the loop the current falls to \(5/110 = 45.5\,\text{mA}\), about 9% low. Lower current ranges of the same meter usually have higher internal resistance, so the range you choose matters.

Getting the sign right

Meters have a positive input, usually with a red lead, and a common input, usually black. For an ammeter to give a positive reading on a digital meter, or an up-scale reading on an analogue one, conventional current must enter the red lead and leave by the black. For a voltmeter, a positive reading means the red lead is on the higher potential. So to measure \(V_{ab}\), put red on a and black on b. To measure a single-subscript voltage such as \(V_a\), put red on a and black on ground. Reverse the leads and a digital meter simply shows a minus sign, while an analogue pointer tries to swing below zero.

Worked example: predicting meter readings

A 12 V source has its positive terminal at node a and its negative at node 0. \(R_1 = 4.7\,\text{k}\Omega\) runs from a to b and \(R_2 = 3.3\,\text{k}\Omega\) from b to node 0. 1. Current: \(I = 12/8.0\,\text{k}\Omega = 1.50\,\text{mA}\). 2. Drops: \(V_1 = 7.05\,\text{V}\), \(V_2 = 4.95\,\text{V}\). 3. Red on a, black on b: \(+7.05\,\text{V}\), which is \(V_{ab}\). 4. Red on b, black on a: \(-7.05\,\text{V}\). 5. Red on b, black on ground: \(+4.95\,\text{V}\), which is \(V_b\). 6. An ammeter inserted between the source and \(R_1\), red towards the source, reads \(+1.50\,\text{mA}\); with the leads swapped it reads \(-1.50\,\text{mA}\).

Never put an ammeter across a source

Because an ammeter's resistance is very small, connecting it across a source or a component, as though it were a voltmeter, places an almost perfect short circuit there. The current is then limited only by the meter and the source's internal resistance, and it can blow the meter's fuse, damage the meter or the source, or overheat the leads. The same reasoning means you cannot use an ohmmeter on a live circuit: an ohmmeter works by passing its own small current, and any voltage already present corrupts the reading and may damage the meter. Ohmmeters are for parts with the power removed.

Measuring internal resistance safely

The topic Internal resistance and voltage regulation modelled a source as \(E\) in series with \(R_{int}\). You cannot measure \(R_{int}\) with an ohmmeter, because the source is live. The no-load voltage is easy: a voltmeter across the bare terminals draws so little current that it reads \(V_{NL}\) almost exactly. Shorting the terminals through an ammeter would give the short-circuit current, but with a small \(R_{int}\) that current can be large enough to damage the meter, the source or you. The safer method is to connect a resistive load that draws about half the rated current, measure the terminal voltage, and use \(R_{int} = (V_{NL} - V_L)/I_L\).

Worked example: a load test

A supply rated for 2.0 A reads 15.00 V with no load. 1. Choose a load for about half the rated current: \(15\,\text{V}/1.0\,\text{A} = 15\,\Omega\), checking that the resistor's power rating exceeds the roughly 15 W it will dissipate. 2. With the load connected, the terminals read 14.70 V. 3. Load current: \(I_L = 14.70/15 = 0.980\,\text{A}\). 4. Internal resistance: \(R_{int} = 0.30\,\text{V}/0.980\,\text{A} = 0.306\,\Omega\). 5. Check: the drop, \((0.980)(0.306) = 0.30\,\text{V}\), accounts for the whole difference between 15.00 V and 14.70 V.

Finding an open in a series string

When a series circuit goes dead, a voltmeter finds the fault quickly. With the supply on and one element open, no current flows, so every intact element has \(IR = 0\) across it, and the open element has the full supply voltage across it. Move the voltmeter from element to element: the one that reads the supply voltage is the break. Decorative light strings use this effect cleverly. Each small bulb on a 120 V series string of 50 runs at about 2.4 V and contains a coated shunt wire. If a filament breaks, the full 120 V appears across that bulb, punches through the coating and welds the shunt, so the rest relight.

Series loops as safety circuits

Because one opening anywhere stops the whole current, series connections make natural safety and alarm circuits. Microwave ovens use door switches wired in series, so the power unit can run only when every switch is closed. A simple burglar alarm wires door and window sensors in series with a relay coil: while all are closed the coil is energised, and opening any sensor drops the relay and sounds the alarm. Wire resistance matters in long loops. With 12 V and a 2.4 kΩ coil, 60 Ω of wiring leaves 11.7 V for the coil, but 600 Ω leaves only 9.6 V, which may be too little to hold the relay.

Common mistakes to avoid

First, connecting an ammeter across an element instead of in series, which shorts it out and may blow the meter's fuse. Second, trusting a current reading taken with a meter whose resistance is a sizeable fraction of the circuit's. Third, reading a negative display as a fault; it usually means the leads are reversed. Fourth, using an ohmmeter on powered equipment. Fifth, assuming the element with 0 V across it in a dead series string is the broken one; it is the element with the full supply voltage.

Key takeaways

Ammeters go in series and voltmeters go across. An ammeter's resistance should be far below the branch resistance; near 10% the error becomes significant. For positive readings, current enters the red lead of an ammeter, and a voltmeter's red lead goes on the higher point: red on a and black on b for V_ab, black on ground for V_a. Never put an ammeter across a source or use an ohmmeter on a live circuit. Find R_int from V_NL and a load near half rated current. In a dead series string, the open part has the full supply voltage across it.

Flashcards

Flashcard

Ammeter placement

In series with the branch, after opening the circuit

It measures the current through itself.

Test your understanding

Question 1 of 5

You want to measure the current through one resistor in a series circuit. How should the ammeter be connected?

Question 2 of 5

A 9 V source drives a 150 Ω resistor. An ammeter with 15 Ω of resistance is inserted in the loop. What does it read?

Question 3 of 5

In a series circuit V_ab = +7.05 V. A digital meter is connected with its red lead on b and its black lead on a. What does it show?

Question 4 of 5

Which is the recommended way to find the internal resistance of a live dc supply?

Question 5 of 5

Six lamps are in series across 24 V and all are dark. A voltmeter reads 24 V across lamp 4 and 0 V across each of the others. What is the fault?

← Previous topicNext topic →