Electrical Engineering › Section C · Series circuits › Topic C.3
The voltage divider rule and notation
A series string shares its voltage out in proportion to resistance, and one short rule tells you each share without finding the current first. Add a clear way to name voltages at points and between points, and you can read any schematic's voltage levels.
Voltage divides as resistance
In a series circuit every resistor carries the same current, so each voltage \(V = IR\) is in proportion to its resistance. A resistor three times another takes three times the voltage. What matters is the ratio of the resistances, not their size. Multiply every resistor in a string by 1,000 and each voltage stays exactly the same, though the current falls to a thousandth. A large ratio means a lopsided split: with 100 kΩ and 100 Ω in series across 10 V, the 100 Ω resistor has only about 9.99 mV across it, and almost all of the 10 V sits on the 100 kΩ.
The voltage divider rule
Combine \(I = E/R_T\) with \(V_x = IR_x\) and the current cancels out:
This is the voltage divider rule (VDR). The voltage across any series resistor equals its resistance, divided by the total series resistance, times the total voltage across the string. The rule extends to a group of adjacent series resistors: put their combined resistance \(R'\) in the numerator to get \(V' = R'E/R_T\). And \(E\) need not be a source. It can be any known voltage across a string of series elements, such as a voltage you have just found with KVL.
Worked example: three resistors on 9 V
A 9 V source drives \(R_1 = 10\,\text{k}\Omega\), \(R_2 = 4.7\,\text{k}\Omega\) and \(R_3 = 3.3\,\text{k}\Omega\) in series. 1. Total: \(R_T = 18\,\text{k}\Omega\). 2. VDR for each: \(V_1 = \frac{10}{18}(9) = 5.0\,\text{V}\), \(V_2 = \frac{4.7}{18}(9) = 2.35\,\text{V}\), \(V_3 = \frac{3.3}{18}(9) = 1.65\,\text{V}\). 3. Across \(R_2\) and \(R_3\) together: \(V' = \frac{8.0}{18}(9) = 4.0\,\text{V}\), which is \(2.35 + 1.65\). 4. Check with KVL: \(5.0 + 2.35 + 1.65 = 9.0\,\text{V}\). The current, 0.5 mA, was never needed, though it confirms \(V_1 = (0.5\,\text{mA})(10\,\text{k}\Omega)\).
Worked example: scaling a battery for an ADC
A microcontroller's analogue-to-digital converter (ADC) accepts at most 3.3 V, but it must watch a 12 V battery that reaches about 14.4 V while charging. 1. Needed ratio: \(3.3/14.4 = 0.229\) or less. 2. Try \(R_1 = 39\,\text{k}\Omega\) from the battery to the ADC pin and \(R_2 = 10\,\text{k}\Omega\) from the pin to ground: ratio \(10/49 = 0.204\). 3. Outputs: \(14.4 \times 0.204 = 2.94\,\text{V}\) at full charge, and \(12 \times 0.204 = 2.45\,\text{V}\) at 12 V. 4. Drain: \(14.4\,\text{V}/49\,\text{k}\Omega = 0.294\,\text{mA}\), small enough to leave connected. 5. Check: 2.94 V is safely below 3.3 V.
Choosing divider values
Only the ratio sets the output, so the designer chooses the size. Large values waste less current, which matters on a battery, but the output is then easily pulled down by whatever it feeds, as the topic Loaded voltage dividers and potentiometers shows. Small values hold the output firm but draw more current. Tolerance matters too. With 5% parts in the ADC divider, the ratio could lie anywhere from about 0.188 to 0.221, so 14.4 V could read between about 2.71 V and 3.18 V. Resistive sensors use the same rule: put a thermistor in place of \(R_2\) and the output voltage tracks temperature.
Ground and reference
Voltage always exists between two points, so a circuit needs a reference. Most systems use ground, a common point defined as 0 V, called node 0 in this course. Schematics often save space by showing a supply as a label such as +12 V at a terminal, which means a source sits between that terminal and ground with its positive side at the terminal. A label of −5 V means the terminal is 5 V below ground. Every ground symbol in a drawing is connected, even where no wire is drawn between them, so current has a complete path.
Double and single subscripts
The double-subscript voltage \(V_{ab}\) means the potential of point a measured with respect to point b. It is positive when a is the higher point and negative when b is higher, so \(V_{ba} = -V_{ab}\). The single-subscript voltage \(V_a\) means the potential of a with respect to ground. The two notations are linked by a rule used constantly in electronics:
If \(V_a = 10\,\text{V}\) and \(V_b = 4\,\text{V}\), then \(V_{ab} = 6\,\text{V}\). If instead \(V_b = -15\,\text{V}\) and \(V_a = 20\,\text{V}\), then \(V_{ab} = 35\,\text{V}\): the minus sign must be kept.
Worked example: a split supply
Point a is held at +12 V and point d at −3 V by two supplies referred to ground. Between them, in series from a to d, are \(R_1 = 1.0\,\text{k}\Omega\) from a to b, \(R_2 = 2.2\,\text{k}\Omega\) from b to c and \(R_3 = 1.8\,\text{k}\Omega\) from c to d. 1. Total voltage across the string: \(V_{ad} = 12 - (-3) = 15\,\text{V}\). 2. VDR drops: 3.0 V, 6.6 V and 5.4 V. 3. Step down from a: \(V_b = 12 - 3.0 = 9.0\,\text{V}\), \(V_c = 9.0 - 6.6 = 2.4\,\text{V}\). 4. Check: \(V_d = 2.4 - 5.4 = -3.0\,\text{V}\). 5. Then \(V_{bd} = 9.0 - (-3.0) = 12\,\text{V}\) and \(V_{cb} = 2.4 - 9.0 = -6.6\,\text{V}\).
Reading levels as a map
Thinking of potentials as heights on a map makes notation easier. Start at ground, climb by each source's voltage, and descend by each resistor drop, writing the level at every node as you go. Then any double-subscript voltage is just the difference between two heights. In the split-supply example, the levels from a to d are +12, +9.0, +2.4 and −3.0 V. Engineers mark such expected levels on schematics so that a technician with a meter can check, point by point against ground, whether a board is working.
Common mistakes to avoid
First, putting the wrong resistor in the numerator: the voltage across \(R_x\) uses \(R_x\) on top and the whole series total underneath, not the other resistor. Second, using the VDR on resistors that are not in series, such as a divider whose output feeds a significant load. Third, losing a minus sign in \(V_{ab} = V_a - V_b\) when one point is negative: \(20 - (-15)\) is 35, not 5. Fourth, reading \(V_{ab}\) backwards; the first subscript is the point being measured, the second is the reference.
Key takeaways
Series voltages divide in proportion to resistance, and only the ratios matter. The voltage divider rule: V_x = R_x E / R_T, which also works for a group of adjacent resistors and for any known voltage across a string. Divider design trades current drain against stiffness, and tolerance spreads the output. Ground is the 0 V reference. V_ab is the potential of a with respect to b, V_a is with respect to ground, and V_ab = V_a − V_b, with V_ba = −V_ab.
Flashcards
Flashcard
V_x = R_x E / R_T
Test your understanding
Question 1 of 5
A 24 V source drives R1 = 4.7 kΩ and R2 = 3.3 kΩ in series. What is the voltage across R2?
Question 2 of 5
Point a is at +5 V and point b is at −7 V, both measured from ground. What is V_ab?
Question 3 of 5
Every resistor in a series divider is replaced with one 1,000 times larger, with the same source. What happens?
Question 4 of 5
A schematic gives V_ba = +6 V. What does that tell you?
Question 5 of 5
A divider has 39 kΩ from a 14.4 V battery to an output pin and 10 kΩ from the pin to ground. What is the output voltage, with nothing loading it?