Electrical Engineering › Section H · Magnetic circuits and inductors › Topic H.1

Magnetic fields, flux density, and permeability

Motors, transformers, relays, loudspeakers and every inductor work through magnetic fields. This topic sets up the three quantities you need to describe those fields in a circuit: flux, flux density and permeability.

Why magnetism belongs in a circuits course

In about 1820 the Danish physicist Hans Christian Oersted noticed that a wire carrying current swings a nearby compass needle, the first sign that electricity and magnetism are linked. André-Marie Ampère in France took up the study the same year. Today almost every machine that turns electrical energy into motion, or moves energy from one winding to another, relies on a magnetic field set up by current. Before you can analyse a transformer core or an inductor, you need a precise language for that field.

Field lines and what they show

A magnetic field is drawn with flux lines. Electric field lines start and end on charges, but magnetic flux lines have no ends: every line is a closed loop. Outside a bar magnet the lines run from its N end round to its S end, then continue through the magnet back to N. Lines never cross, and where they crowd together the field is stronger, which is why a magnet grips hardest at its poles. Flux passes far more easily through iron than through air, glass or copper, so a soft-iron case around a sensitive meter steers stray flux round it: magnetic shielding.

Fields made by currents

Every current-carrying conductor is circled by flux lines. For a straight wire, point your right thumb along the conventional current and your fingers curl the way the field goes. Wind the wire into a coil and the field resembles a bar magnet's: curl your right fingers along the current in the turns and your thumb points to the north pole, the end where flux leaves. An iron core inside the coil concentrates the flux, making an electromagnet that can be switched or reversed. On a cross-section, a dot means current towards you and a cross means current away. Electron-flow books state these as left-hand rules; this course uses conventional current, so always use the right hand.

Flux and flux density

Magnetic flux, symbol \(\Phi\), measures the total amount of field passing through a surface. Its SI unit is the weber (Wb). Flux density, symbol \(B\), is the flux per unit area through a surface at right angles to the field:

B = \frac{\Phi}{A}

Its unit is the tesla, with \(1\,\text{T} = 1\,\text{Wb/m}^2\). Some meters still read in gauss, the older CGS unit: 1 T = 10,000 G. For scale, the Earth's field at the surface is about 25 to 65 µT, and hospital MRI scanners typically run at 1.5 T or 3 T.

Worked example: flux density in a core

A transformer core has a rectangular cross-section 20 mm by 30 mm and carries a flux of 0.45 mWb. Find the flux density in teslas and gauss. 1. Convert the area to square metres first: \(A = 0.020 \times 0.030\,\text{m}^2\), which is \(6.0 \times 10^{-4}\,\text{m}^2\). 2. Divide:

B = \frac{0.45 \times 10^{-3}\,\text{Wb}}{6.0 \times 10^{-4}\,\text{m}^2} = 0.75\,\text{T}

3. In gauss: \(0.75 \times 10{,}000 = 7500\,\text{G}\). 4. Check: steel cores are usually run at flux densities below about 1.5 T, so 0.75 T is a sensible working level.

Flux through a tilted surface

When the field does not meet a surface head-on, only part of it passes through. Measure the angle \(\theta\) between the field and the normal, the line perpendicular to the surface. For a uniform field,

\Phi = BA\cos\theta

Face-on, \(\theta = 0^\circ\) and the flux is a maximum, \(BA\). Edge-on, with the field lying in the plane of the surface, \(\theta = 90^\circ\) and no flux passes through. Turning a coil therefore changes its flux without changing the field, an idea central to the topic "Faraday's and Lenz's laws".

Worked example: a loop at an angle

A rectangular loop 12 cm by 8.0 cm sits in a uniform field of 0.40 T, with its normal at \(60^\circ\) to the field. Find the flux through it. 1. Area: \(A = 0.12 \times 0.080\,\text{m}^2\), which is \(9.6 \times 10^{-3}\,\text{m}^2\). 2. Apply the cosine:

\Phi = (0.40)(9.6 \times 10^{-3})\cos 60^\circ

3. Since \(\cos 60^\circ = 0.5\), \(\Phi = 1.92 \times 10^{-3}\,\text{Wb}\), or 1.92 mWb. 4. Check: face-on the flux would be 3.84 mWb, and \(\cos 60^\circ\) halves it. If a problem instead gives \(30^\circ\) between the field and the plane of the loop, the normal is still at \(60^\circ\) and the answer is the same.

Force on a current: what a tesla means

A field also pushes on any current that crosses it. A straight conductor of length \(l\) carrying current \(I\) at right angles to a uniform field feels \(F = BIl\), at right angles to both the wire and the field; reverse the current or the field and the force reverses. This gives the unit a physical meaning: 1 T pushes with 1 N on each metre of wire carrying 1 A across it. So 0.25 m of wire carrying 8.0 A across a 0.50 T field feels

F = (0.50)(8.0)(0.25) = 1.0\,\text{N}

Motors and loudspeakers run on this force.

Permeability

Put cores of different materials into the same coil with the same current and the flux differs enormously. Permeability, symbol \(\mu\), measures how readily a material lets flux be set up in it, much as conductivity measures how readily it carries current. Its unit is the henry per metre, H/m, the same as Wb/(A·m). For free space,

\mu_0 = 4\pi \times 10^{-7}\,\text{H/m}

Since the 2019 SI revision this is a measured value, but it matches \(4\pi \times 10^{-7}\) to better than one part in a billion. Air, copper, aluminium and glass are so close to \(\mu_0\) that circuit work treats them as equal to it.

Relative permeability and material classes

Relative permeability compares a material with free space: \(\mu_r = \mu / \mu_0\), a pure number. Diamagnetic materials, such as copper, water and bismuth, have \(\mu_r\) a whisker below 1; paramagnetic ones, such as aluminium and platinum, a whisker above 1. Ferromagnetic materials, namely iron, nickel, cobalt and their alloys, have \(\mu_r\) in the hundreds or thousands, and some special alloys exceed 100,000. A steel with \(\mu_r = 2000\) has \(\mu = 2000\mu_0 \approx 2.51 \times 10^{-3}\,\text{H/m}\). For ferromagnetic materials \(\mu_r\) is not a constant: it changes with how hard the material is magnetised, as the topic "Reluctance, magnetizing force, and hysteresis" shows.

Common mistakes to avoid

First, leaving areas in mm² or cm²: 1 mm² is \(10^{-6}\,\text{m}^2\), 1 cm² is \(10^{-4}\,\text{m}^2\), and the tesla needs square metres. Second, measuring the angle from the surface instead of its normal, which swaps sine for cosine. Third, mixing up \(\Phi\), total flux in webers, with \(B\), flux per square metre in teslas. Fourth, treating the \(\mu_r\) of iron as a fixed number. Fifth, using a left-hand rule from an electron-flow book with conventional current.

Key takeaways

Magnetic flux lines form closed loops, run north to south outside a magnet and crowd together where the field is strong. Currents make fields: right thumb along the current for a wire, right fingers along the current for a coil with the thumb at the north pole. Flux \(\Phi\) is in webers; flux density \(B = \Phi/A\) is in teslas, and \(\Phi = BA\cos\theta\) for a tilted surface. A wire across a field feels \(F = BIl\). Permeability \(\mu = \mu_r\mu_0\), with \(\mu_0 = 4\pi \times 10^{-7}\,\text{H/m}\); ferromagnetic materials have \(\mu_r\) in the hundreds to thousands.

Flashcards

Flashcard

Magnetic flux line

A closed loop showing the field's direction; lines never cross

Outside a magnet they run from N to S.

Test your understanding

Question 1 of 5

A core with a cross-section of 25 mm by 40 mm carries a flux of 0.80 mWb. What is the flux density?

Question 2 of 5

A flat loop of area 0.050 m² sits in a uniform 0.60 T field. The angle between the field and the plane of the loop is 30°. What flux passes through the loop?

Question 3 of 5

A steel has a relative permeability of 2500 at its working flux density. What is its permeability?

Question 4 of 5

You look at the left end of a coil and see conventional current going round the turns anticlockwise. Which end is the north pole?

Question 5 of 5

A 0.40 m length of wire carries 5.0 A at right angles to a uniform 0.30 T field. What force acts on it?

← Previous topicNext topic →