Electrical Engineering › Section D · Parallel and series-parallel circuits › Topic D.8
Meter design and grounding
With series and parallel circuits mastered, you can design an ammeter, a voltmeter and an ohmmeter from one small meter movement. The same reasoning explains grounding: why a ground reference matters, how a test lead can short out a circuit, and how a ground wire makes an appliance safe.
One movement, three instruments
Digital multimeters now dominate the bench, but the classic analogue meter neatly sums up this section. Its heart is a sensitive movement that shows only a tiny current. Add a resistor in parallel and it becomes an ammeter; add one in series and it becomes a voltmeter; add a battery and it becomes an ohmmeter. Each design is a short exercise in Ohm's law, KCL and KVL. The topic then turns to grounding, where the same thinking decides whether a measurement is sound and whether a fault is dangerous.
The d'Arsonval movement
In a d'Arsonval movement, a light pivoted coil sits between the poles of a permanent magnet. Coil current produces a torque that turns it against small springs, so the pointer's deflection is proportional to the current; reversed current drives it below zero, which is why meter terminals are marked + and −. A movement is specified by two numbers: its full-scale current \(I_{CS}\), the current sensitivity, and its coil resistance \(R_m\). The examples here use a movement rated 100 µA and 1.0 kΩ, which reaches full scale with only \(100\,\mu\text{A} \times 1.0\,\text{k}\Omega = 0.1\,\text{V}\) across it.
Ammeters: the shunt
To measure currents larger than \(I_{CS}\), a low resistance called a shunt goes in parallel with the movement and carries the excess. At full scale the movement takes \(I_{CS}\) and, by KCL, the shunt takes \(I_{\max} - I_{CS}\). The two share one voltage, so \(I_{CS}R_m = (I_{\max} - I_{CS})R_{sh}\), giving
A rotary switch selecting among several shunts makes a multirange ammeter. Because the shunt is tiny, the whole ammeter has a very low resistance, right for an instrument inserted in series, and the reason an ammeter connected across a source acts as a short circuit.
Worked example: a two-range ammeter
Design shunts that turn the 100 µA, 1.0 kΩ movement into an ammeter with 10 mA and 1 A ranges. 1. The movement voltage at full scale is \(I_{CS}R_m = 0.1\,\text{V}\). 2. On the 10 mA range the shunt carries \(10 - 0.1 = 9.9\,\text{mA}\), so \(R_{sh} = 0.1 / 9.9\,\text{mA} = 10.1\,\Omega\). 3. On the 1 A range it carries 0.9999 A, so \(R_{sh} = 0.1 / 0.9999 = 0.100\,\Omega\), to three significant figures. 4. Check the meter's own resistance on the 10 mA range: \(10.1\,\Omega \parallel 1.0\,\text{k}\Omega = 10.0\,\Omega\), small enough to disturb most circuits very little. On the 1 A range, a few milliohms of contact resistance would already cause a noticeable error.
Voltmeters: the multiplier
To measure voltage, a large resistance called a multiplier goes in series with the movement, limiting the current to \(I_{CS}\) when the full-scale voltage is applied. By KVL, \(V_{\max} = I_{CS}(R_s + R_m)\), so
The total meter resistance, \(V_{\max} / I_{CS}\) (the whole-meter \(R_m\) of "Voltmeter loading effects", not the coil's), is proportional to the range, which is where that topic's ohms-per-volt rating comes from: \(S = 1 / I_{CS}\). A 1 mA movement gives 1 kΩ/V, our 100 µA movement 10 kΩ/V, and a 50 µA movement 20 kΩ/V. A more sensitive movement therefore makes a voltmeter that loads circuits less.
Worked example: a two-range voltmeter
Use the 100 µA, 1.0 kΩ movement to build a voltmeter with 10 V and 50 V ranges. 1. 10 V range: the total resistance must be \(10 / 100\,\mu\text{A} = 100\,\text{k}\Omega\), so \(R_s = 100 - 1.0 = 99\,\text{k}\Omega\). 2. 50 V range: total \(500\,\text{k}\Omega\), so \(R_s = 499\,\text{k}\Omega\). 3. Sensitivity: \(S = 1 / 100\,\mu\text{A} = 10\,\text{k}\Omega/\text{V}\); check that \(10\,\text{V} \times 10\,\text{k}\Omega/\text{V} = 100\,\text{k}\Omega\). 4. A half-scale reading on the 50 V range means 50 µA in the movement, so the measured voltage is 25 V.
The series ohmmeter
A series ohmmeter puts a battery, a fixed resistor and an adjustable zero-adjust resistor in series with the movement and the test terminals. With the terminals shorted, the internal resistance is set so the movement reads full scale; for a 1.5 V cell and our movement, that total is \(1.5 / 100\,\mu\text{A} = 15\,\text{k}\Omega\). An unknown \(R_x\) then gives \(I = 1.5 / (15\,\text{k}\Omega + R_x)\). So 15 kΩ reads half scale, 5 kΩ three-quarters and 45 kΩ a quarter: the scale runs backwards and is crowded at the high end. At the extremes, a milliohmmeter measures tiny resistances and a megohmmeter applies a high test voltage, often 500 V or 1000 V, to check insulation resistance.
Ground as a reference
A ground symbol marks the point defined as 0 V, the reference for every schematic voltage. An earth ground is a low-resistance connection to the earth itself, such as the rod bonded to a building's service panel. A chassis ground is the metal frame used as the circuit's reference; it may be earthed or floating at some other potential. The trap is test equipment. Many oscilloscopes tie their probe ground clips to earth through the power cord, and some bench supplies earth their − terminal. Clip the scope ground to any node other than circuit ground and you connect that node to ground through the earth.
Worked example: a probe ground that shorts a resistor
A bench supply with its − terminal earthed provides 12 V. A 10 Ω sense resistor \(R_1\) runs from + to node a, and a 1.0 kΩ load \(R_2\) from a to ground. An earthed oscilloscope views \(R_1\), tip at + and ground clip at a. 1. Normally \(I = 12 / 1010 = 11.9\,\text{mA}\), and \(R_1\) dissipates about 1.4 mW. 2. The clip joins a to earth, which is the supply's −, so \(R_2\) is shorted out. 3. Now \(I = 12 / 10 = 1.2\,\text{A}\), and \(R_1\) must dissipate \(1.2^2 \times 10 = 14.4\,\text{W}\), enough to destroy a small resistor. 4. Fixes: put \(R_1\) at the ground end, or measure each end to ground on two channels and subtract.
Ground wires and safety
In US wiring, the National Electrical Code reserves white or grey insulation for the neutral that returns current and green or bare copper for the equipment ground; hot conductors are usually black or red. The ground wire carries no current in normal use. Consider a 1200 W toaster on 120 V: it draws 10 A, comfortably below a 20 A breaker. If a frayed hot wire touches its ungrounded metal case, the current is still 10 A, so the breaker stays on while the case sits at 120 V. With the case grounded, the fault becomes a near short to ground, the current soars and the breaker opens.
Common mistakes to avoid
First, computing a shunt with \(I_{\max}\) instead of \(I_{\max} - I_{CS}\); the difference matters on low ranges. Second, forgetting to subtract \(R_m\) when finding a multiplier. Third, reading an ohmmeter scale as linear. Fourth, measuring resistance in a powered circuit; an ohmmeter supplies its own current and the reading means nothing with the circuit live. Fifth, clipping an earthed oscilloscope's ground lead to a node that is not circuit ground. Sixth, treating the green ground wire as a spare return conductor; it is there to carry fault current only.
Key takeaways
A d'Arsonval movement is rated by its full-scale current \(I_{CS}\) and resistance \(R_m\). An ammeter adds a parallel shunt, \(R_{sh} = R_m I_{CS} / (I_{\max} - I_{CS})\), giving a low meter resistance. A voltmeter adds a series multiplier, \(R_s = V_{\max} / I_{CS} - R_m\), and its sensitivity is \(S = 1 / I_{CS}\) ohms per volt. A series ohmmeter reads full scale at 0 Ω, half scale when \(R_x\) equals its internal resistance, and backwards. Earthed test equipment can short circuit nodes, and a grounded case turns a dangerous fault into a tripped breaker.
Flashcards
Flashcard
Coil turning in a permanent magnet's field; deflection ∝ current
Test your understanding
Question 1 of 5
A 1 mA, 50 Ω movement is to read 100 mA at full scale. What shunt resistance is needed?
Question 2 of 5
The same 1 mA, 50 Ω movement is to read 20 V at full scale. What series multiplier is needed?
Question 3 of 5
A voltmeter is built from a 50 µA movement. What is its sensitivity?
Question 4 of 5
A series ohmmeter has a total internal resistance of 15 kΩ when zeroed. Where does the pointer sit for a 15 kΩ resistor?
Question 5 of 5
A metal-cased appliance develops a fault in which the hot wire touches its case. Why does a ground wire on the case make this safer?