Electrical Engineering › Section M · Transformers and polyphase systems › Topic M.3
Reflected impedance and impedance matching
Seen from its primary, a transformer makes its load look larger or smaller by the square of the turns ratio. That lets engineers match a speaker to an amplifier, feed many loudspeakers from one line, and keep two circuits electrically apart.
What the source sees
Connect a load \(Z_L\) to the secondary of an ideal transformer and drive the primary from a source. The source cannot see the load directly; it sees only the voltage across the primary and the current it supplies. The ratio of those two is the input impedance \(Z_p\), the impedance the load appears to have from the primary side. This topic uses the ideal transformer of "The iron-core transformer and power transmission", with transformation ratio \(a = N_p/N_s\), so that \(\mathbf{V}_p = a\mathbf{V}_s\) and \(\mathbf{I}_p = \mathbf{I}_s/a\), with all voltages and currents as rms phasors.
The a-squared rule
Divide the primary voltage by the primary current:
The load is reflected into the primary multiplied by \(a^2\). Two consequences follow. A step-down transformer (\(a > 1\)) makes a small load look large, and a step-up transformer (\(a < 1\)) makes a large load look small. And because \(a^2\) is a positive real number, the angle of the impedance is unchanged: an inductive load still looks inductive, a capacitive load still looks capacitive, and both the resistance and the reactance scale by \(a^2\).
Power is reflected too
An ideal transformer stores and wastes nothing, so the real power entering the primary equals the real power delivered to the load: \(P_\text{in} = P_\text{out}\). The reflected resistance \(a^2R_L\) therefore absorbs exactly the power the real load absorbs, and the reflected reactance accounts for the same reactive power. This gives a quick way to analyse a transformer circuit. Replace the transformer and its load by the single impedance \(a^2Z_L\), solve the primary circuit with the methods of the ac sections, then return to the secondary with \(\mathbf{I}_s = a\mathbf{I}_p\) and \(\mathbf{V}_s = \mathbf{V}_p/a\).
Worked example: an inductive load
A 5 : 1 step-down transformer (\(a = 5\)) is fed from 120 V and supplies a load \(Z_L = 6 + j8\,\Omega\), in rectangular form. Find the primary impedance, both currents, the load voltage and the load power. 1. Reflect: \(Z_p = 25(6 + j8) = 150 + j200\,\Omega\), which is \(250\angle 53.1^\circ\,\Omega\) in polar form. 2. Primary current: \(I_p = 120/250 = 0.480\,\text{A}\), lagging the supply by 53.1°. 3. Secondary current: \(I_s = aI_p = 2.40\,\text{A}\). 4. Load voltage: \(V_s = 2.40 \times 10.0 = 24.0\,\text{V}\), which is 120/5, as expected. 5. Power: \(I_s^2R_L = 2.40^2 \times 6 = 34.6\,\text{W}\), and the primary side gives \(0.480^2 \times 150 = 34.6\,\text{W}\) too.
Looking back towards the source
The rule works in both directions. Seen from the secondary, anything on the primary side is divided by \(a^2\). A source of open-circuit voltage \(\mathbf{V}_g\) and internal impedance \(Z_g\) on the primary looks, from the secondary terminals, like a Thevenin source of voltage \(\mathbf{V}_g/a\) and impedance \(Z_g/a^2\). A step-down transformer therefore turns a high-impedance source into a lower-impedance one at a lower voltage. This is often the easiest way to find a load voltage: move everything to one side of the transformer, using the method of "Thevenin and Norton (ac)", and solve a single loop.
Impedance matching for maximum power
From "Maximum power transfer and other theorems (ac)", a resistive load takes the most power from a source of internal resistance \(R_g\) when the two are equal. Few real loads happen to match their source: a loudspeaker is a few ohms, while many sources have internal resistances of hundreds of ohms. A transformer fixes the mismatch by making the load look like \(R_g\). Set \(a^2R_L = R_g\) and solve:
At the match, the source delivers maximum power to the load, though half the power it generates is lost in its own internal resistance, so matching suits signal circuits rather than power distribution.
Worked example: matching a speaker
A source of 10.0 V rms with internal resistance 200 Ω drives an 8 Ω speaker. Find the speaker power without and with a matching transformer. 1. Direct: \(I = 10.0/(200 + 8) = 48.1\,\text{mA}\), so \(P = 0.0481^2 \times 8 = 18.5\,\text{mW}\). 2. Turns ratio: \(a = \sqrt{200/8} = 5\), so the speaker reflects as \(25 \times 8 = 200\,\Omega\). 3. Primary current: \(I_p = 10.0/(200 + 200) = 25.0\,\text{mA}\), and the reflected 200 Ω takes \(0.025^2 \times 200 = 125\,\text{mW}\). 4. Check on the secondary: \(I_s = 5 \times 25.0 = 125\,\text{mA}\), and \(0.125^2 \times 8 = 125\,\text{mW}\). The transformer raised the speaker power by a factor of about 6.8.
Constant-voltage speaker lines
Public-address systems in schools and shops often run a 70.7 V line, chosen because its peak value is 100 V, with a small transformer at each speaker. Here the aim is not matching: the amplifier holds the line at 70.7 V, and each transformer's primary tap sets how much power its speaker draws. A 5 W tap must present \(Z_p = V^2/P = 70.7^2/5 = 1.00\,\text{k}\Omega\). For an 8 Ω speaker that needs \(a = \sqrt{1000/8} = 11.2\), and the speaker receives \(\sqrt{5 \times 8} = 6.32\,\text{V}\). Four such speakers in parallel load the line with 250 Ω and draw 20 W in total, so installers add speakers until the amplifier's rating is reached.
Isolation
A two-winding transformer has no conductive path between primary and secondary; energy crosses only through the magnetic field. That isolation has several uses. Voltage transformers on high-voltage lines step tens of kilovolts down to about 120 V, so meters and relays can be connected without touching the line. On a test bench, a 1 : 1 isolation transformer lets a grounded oscilloscope probe a circuit without its ground lead shorting part of that circuit through the mains earth. Isolation also blocks a dc level while passing the ac signal. It is not a guarantee of safety: a voltage across the secondary itself can still drive current through a person who touches both terminals.
Sensing displacement: the LVDT
The linear variable differential transformer, or LVDT, uses transformer action to measure position. It has a primary winding between two identical secondaries and a movable iron core. An ac voltage drives the primary, and the two secondaries are connected so that their voltages subtract. With the core centred, both secondaries link equal flux and the output is close to zero. Move the core either way and one secondary links more flux than the other, so the output grows with the displacement, and its phase shows the direction. Because the core never touches the windings, LVDTs measure small movements with no friction or wear.
Common mistakes to avoid
First, multiplying by a instead of \(a^2\): impedance scales with the square of the turns ratio, voltage and current with the ratio itself. Second, reflecting the wrong way: impedances moved towards the high-voltage side get larger, and those moved towards the low-voltage side get smaller. Third, changing the angle when reflecting; an inductive load stays inductive. Fourth, writing the matching ratio as \(R_g/R_L\) without the square root. Fifth, treating isolation as a safety guarantee; the secondary voltage itself can still give a shock.
Key takeaways
Through an ideal transformer with a = Np/Ns, a load ZL appears at the primary as a²ZL, with the same angle; power in equals power out, so the reflected resistance absorbs the load's real power. Seen from the secondary, primary-side impedances divide by a² and the source voltage by a. For maximum power to a resistive load, choose a = √(Rg/RL). Constant-voltage 70.7 V speaker lines use tap impedances V²/P instead of matching. Transformers also isolate circuits, with no conductive path between windings, and the LVDT turns core displacement into a voltage.
Flashcards
Flashcard
A load seen from the primary of an ideal transformer
Test your understanding
Question 1 of 5
A 10 Ω resistor is connected to the secondary of an ideal transformer with a = Np/Ns = 4. What resistance does the source see at the primary?
Question 2 of 5
A source with 324 Ω internal resistance must deliver maximum power to a 4 Ω speaker. What turns ratio Np : Ns is needed?
Question 3 of 5
A load of 3 + j4 Ω is connected to an ideal transformer with a = 2. What impedance appears at the primary?
Question 4 of 5
On a 70.7 V constant-voltage speaker line, what impedance does a 2.5 W transformer tap present to the line?
Question 5 of 5
Why might a technician power a circuit under test through a 1 : 1 transformer?