Electrical Engineering › Section D · Parallel and series-parallel circuits › Topic D.5

Voltmeter loading effects

A voltmeter is connected in parallel with whatever it measures, so it always becomes part of the circuit. Knowing when that changes the reading, and how to measure and troubleshoot parallel circuits, separates a trustworthy measurement from a misleading one.

Every meter joins the circuit

Placing a voltmeter "across" an element, as earlier topics described, means connecting it in parallel with that element. The meter has an internal resistance \(R_m\), so the act of measuring adds a new parallel branch. An ideal voltmeter would have infinite resistance and draw no current; a real one draws a little. In low-resistance circuits that is negligible. In high-resistance circuits, with resistors in the hundreds of kilohms, the meter can pull the voltage it measures well below its true value. This topic shows how to predict that error, then turns to measuring and fault-finding in parallel circuits.

Why the reading drops

With the meter connected, the element and the meter form a parallel pair, and a parallel combination is always smaller than its smaller member. The measured element therefore looks smaller to the rest of the circuit, so it takes a smaller share of the voltage. Across a 22 kΩ resistor, a digital multimeter (DMM) with 10 MΩ of input resistance makes \(22\,\text{k}\Omega \parallel 10\,\text{M}\Omega = 21.95\,\text{k}\Omega\): practically no change. A meter with only 100 kΩ makes the same resistor behave like 18.0 kΩ, a drop of about 18% that alters every current and voltage in the circuit.

Ohms-per-volt ratings

Most DMMs have an input resistance of about 10 MΩ on every dc voltage range. Analogue multimeters (VOMs) are different: their resistance depends on the range selected. The face of the meter states a sensitivity \(S\) in ohms per volt, and the meter resistance is

R_m = S \times V_{\text{range}}

A typical 20 kΩ/V meter has \(20{,}000 \times 10 = 200\,\text{k}\Omega\) on its 10 V range and 1 MΩ on its 50 V range. So switching a VOM to a higher range can give a more accurate reading, even though the pointer moves less: the higher range loads the circuit less. The topic "Meter design and grounding" shows where this rating comes from.

Worked example: measuring a high-resistance divider

Two 470 kΩ resistors \(R_1\) and \(R_2\) are in series across 15 V, and \(R_2\) runs from node a to ground. Predict the reading of \(V_a\) for three meters. 1. True value: equal resistors halve the source, so \(V_a = 7.50\,\text{V}\). 2. DMM, 10 MΩ: \(R_2 \parallel R_m = 448.9\,\text{k}\Omega\), so by the voltage divider rule \(V_a = 15 \times \frac{448.9}{470 + 448.9} = 7.33\,\text{V}\), about 2% low. 3. VOM, 20 kΩ/V on the 10 V range: \(R_m = 200\,\text{k}\Omega\), the parallel pair is 140.3 kΩ and \(V_a = 3.45\,\text{V}\), less than half the true value. 4. Same VOM on its 50 V range: \(R_m = 1\,\text{M}\Omega\), the pair is 319.7 kΩ and \(V_a = 6.07\,\text{V}\). The higher range reads closer to the truth.

How big a meter resistance is enough

A useful rule of thumb is a factor of 10. For a divider of two equal resistors, a meter resistance 10 times the resistor it is placed across reads about 5% low; 100 times reads about 0.5% low. So before measuring, compare \(R_m\) with the resistances around the points you are probing. Circuits with resistors up to a few tens of kilohms are no challenge for a 10 MΩ DMM; megohm networks and high-resistance sensors are where loading bites. When accuracy matters, check the meter's input resistance against the circuit before trusting a reading, or calculate the expected loading as in the worked example.

Measuring a parallel circuit

Voltage measurements never require breaking the circuit. Because every branch of a parallel group shares one voltage, a single voltmeter across the group measures them all, black lead on the lower-potential side and red on the higher. Currents are different: to measure a branch current you must open that branch and insert the ammeter in series with it, arranged so conventional current enters the meter's + terminal. To read the source current, open the lead between the source and the network. KCL gives a built-in check: the source current must equal the sum of the branch currents, each branch current must be smaller than the source current, and the smaller of two parallel resistors must show the larger current.

Worked example: troubleshooting a divider

A 12 V source feeds \(R_1 = 1.0\,\text{k}\Omega\) from its + terminal to node a, and \(R_2 = 3.3\,\text{k}\Omega\) runs from a to ground. 1. Expected values first: \(I = 12 / 4.3\,\text{k} = 2.79\,\text{mA}\) and \(V_a = 9.21\,\text{V}\). 2. Fault A: \(V_a = 12\,\text{V}\), the drop across \(R_1\) is 0 V and an ammeter in the supply lead reads 0 mA. No drop with no current means \(R_1\) is not shorted, so the circuit is open somewhere from node a through \(R_2\) to ground; a shorted \(R_1\) would also drop 0 V, but would pass 3.64 mA. 3. Fault B: \(V_a = 0.04\,\text{V}\) and \(R_1\) drops 11.96 V. Current flows, so nothing is open, and \(V_a\) is not exactly zero, so \(R_2\) is not shorted, just far too small: a 3.3 Ω part, misread from its colour code, gives exactly this. 4. Fault C: \(V_a = 0\,\text{V}\) exactly with 12 V across \(R_1\): node a is shorted to ground.

Parallel wiring in cars and computers

A car's electrical system is essentially one big parallel circuit. Each load connects between the battery's + terminal, through its own fuse, and the metal chassis, which serves as the return path to the battery's − terminal. The nominal voltage is 12 V, although it rises to about 14 V while the alternator charges. By KCL the battery current is the sum of every branch current, so a 110 W pair of headlights alone adds about 8.7 A at 12.6 V. The starter motor, drawing hundreds of amperes, is usually switched by a relay rather than fused. In a desktop computer, the expansion-card slots are wired in parallel too: each pin joins the same power, ground or signal line on every slot.

Switches in house wiring

"Parallel elements, total conductance, and resistance" showed why home loads are wired in parallel; in the US, lights and outlets run at 120 V and heavy appliances at 240 V. The point for measurement and safety is where the switch sits. A wall switch is in series with the lamp it controls, interrupting the hot conductor, while the outlets on the same circuit have no switch and stay live whenever the breaker in the panel is on. So a wall switch alone does not make a fixture safe to work on: standard practice is to switch off that circuit's breaker and confirm it is dead with a tester.

Common mistakes to avoid

First, trusting a reading in a megohm circuit without asking how much the meter loaded it. Second, assuming a VOM has the same resistance on every range; it scales with the range, so the lowest range loads the most. Third, connecting an ammeter across a branch as if it were a voltmeter, which places a near short circuit across the branch; an ammeter must be inserted in series. Fourth, forgetting that equal voltages across parallel branches need only one voltmeter. Fifth, troubleshooting without first calculating the expected values, which leaves nothing to compare the readings against.

Key takeaways

A voltmeter is a resistance in parallel with what it measures, so it lowers the measured voltage; an ideal meter has infinite resistance. A DMM typically offers about 10 MΩ on every range, while a VOM offers \(R_m = S \times V_{\text{range}}\) from its ohms-per-volt rating. A meter resistance at least 10 times the circuit resistance keeps errors to a few percent. In parallel circuits, one voltmeter covers all branches, but each current needs the branch opened. Troubleshoot by predicting values first: no drop means no current, and exactly 0 V across an element means a short.

Flashcards

Flashcard

Voltmeter connection

In parallel with the element measured

So it adds a parallel branch.

Test your understanding

Question 1 of 5

A 20 kΩ/V analogue meter is set to its 10 V range. What is its internal resistance on that range?

Question 2 of 5

Two 100 kΩ resistors are in series across 10 V. A meter with 100 kΩ of internal resistance is connected across the lower resistor. What does it read?

Question 3 of 5

A VOM reads a high-resistance divider on its 10 V range and again on its 50 V range. Why can the 50 V range give the more accurate reading?

Question 4 of 5

A 12 V source feeds a 1.0 kΩ resistor in series with a 3.3 kΩ resistor to ground. A voltmeter shows 0 V across the 1.0 kΩ resistor and 12 V from the junction to ground, and an ammeter in the supply lead reads 0 mA. What is the fault?

Question 5 of 5

You need the current in one branch of a three-branch parallel circuit. How should the ammeter be connected?

← Previous topicNext topic →