Physics › Section I · Temperature, gases, and heat › Topic I.4

Phase changes, humidity, and boiling

Cool or squeeze a gas enough and it stops obeying the ideal gas law: it turns into a liquid. Phase diagrams map when that happens, and the same physics explains why water boils at lower temperatures on mountains, why dew forms at night and why humid days feel so hot.

When a gas stops being ideal

Cool a gas at constant pressure and its volume shrinks in proportion to its kelvin temperature, as the ideal gas law predicts, until the particles are close enough for their attractions to matter. Then the gas condenses and its volume collapses to that of a liquid, about 1600 times smaller for steam at 100 °C and 1 atm; it never reaches zero, because the particles have a size of their own. Squeezing can also liquefy a gas: carbon dioxide at 25 °C turns liquid at about 63 atm, which is how it is stored in steel cylinders.

PV diagrams and the critical point

A graph of pressure against volume at a fixed temperature is an isotherm. At high temperatures it is the ideal-gas curve, \(PV\) constant. At lower temperatures it has a flat stretch, where gas condenses at constant pressure as the volume is reduced. Above a substance's critical temperature that flat stretch disappears, and no pressure, however high, can produce a separate liquid; above both its critical temperature and pressure, the substance is a supercritical fluid. A gas below its critical temperature, which pressure alone can liquefy, is called a vapour. Critical points: water 374 °C and 218 atm; carbon dioxide 31.0 °C and 72.8 atm; oxygen −119 °C and 49.8 atm; nitrogen −147 °C and 33.5 atm.

Phase diagrams and the triple point

A phase diagram plots pressure against temperature and shows the stable phase in each region; on a boundary line, two phases coexist. The liquid-gas line, the vapour-pressure curve, ends at the critical point. The solid-liquid line gives the melting point at each pressure, and the solid-gas line marks sublimation, solid turning straight into gas. All three lines meet at the triple point, where solid, liquid and gas coexist: for water, 0.01 °C and 611.657 Pa, about 0.006 atm. Below that pressure liquid water cannot exist. Carbon dioxide's triple point is at −56.6 °C and 5.11 atm, so at 1 atm dry ice sublimes, at −78.5 °C, and never melts.

Worked example: warming ice at two pressures

Describe what happens when ice at −20 °C is warmed slowly, first at 1.00 atm, then at a steady 300 Pa. 1. At 1.00 atm, far above the triple-point pressure, the horizontal path crosses the solid-liquid line at 0 °C, where the ice melts. 2. The water then warms until it meets the vapour-pressure curve at 100 °C, and boils. 3. At 300 Pa, below 611.657 Pa, the path never enters the liquid region. 4. The ice warms until its sublimation pressure reaches 300 Pa, at about −8 °C, and there it turns straight to vapour. 5. Check: this is how freeze-drying works, removing ice from frozen food as vapour so it never gets wet.

Evaporation and vapour pressure

Even well below the boiling point, the fastest surface molecules, from the tail of the speed distribution, break free. In a closed jar, vapour builds up until molecules return to the liquid as fast as they leave. The pressure of the vapour in this dynamic equilibrium is the saturation vapour pressure, and it depends only on the substance and the temperature, not on any air present. For water: 0.611 kPa at 0 °C, 1.23 kPa at 10 °C, 2.34 kPa at 20 °C, 4.25 kPa at 30 °C, 47.4 kPa at 80 °C and 101.4 kPa at 100 °C. By Dalton's law, a mixture's total pressure is the sum of its partial pressures, each the pressure that gas alone would exert in the whole volume. Water evaporates while the vapour's partial pressure is below the saturation value.

Boiling

A liquid boils when its saturation vapour pressure equals the pressure on its surface. Then bubbles of vapour, usually starting around tiny pockets of dissolved air, can grow inside the liquid rather than being crushed. At 1 atm water boils at 100 °C. Where the air pressure is about 70 kPa, near 3000 m altitude, it boils at about 90 °C, since that is where its vapour pressure reaches 70 kPa, so food cooks more slowly. A pressure cooker does the opposite: at about 200 kPa absolute, water stays liquid up to roughly 120 °C.

Relative humidity

The relative humidity of air is its water vapour partial pressure as a percentage of the saturation vapour pressure at the air's temperature:

\text{RH} = \frac{p_{\text{vapour}}}{p_{\text{sat}}(T)} \times 100\%

At 100% the air is saturated, and liquid water no longer evaporates into it on balance. Water vapour behaves as an ideal gas, so its density is \(\rho = pM/(RT)\) with \(M = 0.01802\) kg/mol, and RH is also the vapour density divided by the saturation density at the same temperature. Saturated air holds 17.3 g/m³ of vapour at 20 °C and 30.4 g/m³ at 30 °C. People say warm air holds more water, but the limit is set by water's vapour pressure, not by the air.

Dew point and comfort

If air cools while its vapour content stays the same, its relative humidity rises, because the saturation vapour pressure falls. The temperature at which the air becomes saturated is the dew point. Below it, vapour condenses as dew, fog, cloud or a mist on cold glasses; below 0 °C it can form frost instead. You cool yourself by evaporating sweat, and the higher the humidity, the slower the net evaporation, which is why humid heat feels oppressive.

Worked example: humidity and dew point

On a 30.0 °C afternoon the water vapour partial pressure is 2.34 kPa. Find the relative humidity, the dew point and the vapour density. 1. From the table, \(p_{\text{sat}}(30\ ^\circ\text{C}) = 4.25\) kPa. 2. RH: \(2.34/4.25 = 0.551\), so 55.1%. 3. Dew point: 2.34 kPa is the saturation pressure at 20 °C, so the dew point is 20 °C. 4. Density:

\rho = \frac{(2340)(0.01802)}{(8.314)(303.15)} = 0.0167\ \text{kg/m}^3

or 16.7 g/m³. 5. Check by densities: \(16.7/30.4 = 0.549\), the same 55% within rounding.

Worked example: a cold drink on a humid day

A glass of iced water has an outer surface at 10.0 °C in a room at 25.0 °C and 60.0% relative humidity. Will water condense on the glass? Water's saturation vapour pressure is 3.17 kPa at 25 °C and 1.71 kPa at 15 °C. 1. Vapour pressure in the room: \(0.600 \times 3.17 = 1.90\) kPa. 2. Saturation at the glass: 1.23 kPa at 10 °C. 3. Compare: air touching the glass cools to 10.0 °C, and 1.90 kPa is above 1.23 kPa, so that air is oversaturated and dew forms. 4. Check with the dew point: 1.90 kPa lies between 1.71 kPa at 15 °C and 2.34 kPa at 20 °C. Interpolating, \(15 + 5 \times 0.19/0.63 \approx 16.5\) °C, so any surface colder than about 16.5 °C mists over.

Common mistakes to avoid

First, thinking vapour pressure depends on the amount of liquid or on the air above it. Second, dividing by the saturation pressure at the wrong temperature: relative humidity uses the air's own temperature. Third, assuming water always boils at 100 °C; it boils where its vapour pressure equals the surrounding pressure. Fourth, believing any gas can be liquefied by enough pressure; above the critical temperature it cannot. Fifth, confusing the triple point, where three phases coexist, with the critical point, where the liquid-gas line ends.

Key takeaways

Real gases condense when cooled or compressed enough, but not above their critical temperature. A phase diagram's lines are two-phase equilibria, meeting at the triple point (water: 0.01 °C, 611.657 Pa). A liquid's saturation vapour pressure rises with temperature, and it boils when that equals the surrounding pressure. Dalton's law adds partial pressures. Relative humidity is p_vapour/p_sat(T) × 100%, and at the dew point the air is saturated, so dew or fog forms.

Flashcards

Flashcard

Condensation of a real gas

Volume collapses to a liquid's once attractions between particles matter

The ideal gas law fails near it.

Test your understanding

Question 1 of 5

On a 30.0 °C afternoon the partial pressure of water vapour is 1.70 kPa. Water's saturation vapour pressure at 30.0 °C is 4.25 kPa. What is the relative humidity?

Question 2 of 5

For the same air (30.0 °C, vapour pressure 1.70 kPa), estimate the dew point. Water's saturation vapour pressure is 1.71 kPa at 15 °C and 2.34 kPa at 20 °C.

Question 3 of 5

Why does water boil at a lower temperature high on a mountain?

Question 4 of 5

Why does solid carbon dioxide (dry ice) sublime instead of melting when warmed at 1 atm?

Question 5 of 5

Oxygen's critical temperature is −119 °C. A steel cylinder of oxygen at 20 °C is filled to 200 atm. What does it contain?

← Previous topicNext topic →