Transformers and electrical safety

Transformers let the grid raise voltages for efficient long-distance transmission and lower them again for your home, all with no moving parts. Induction also sits inside the devices that make household wiring safer, from the earth wire to the ground fault circuit interrupter.

Two coils, one core

A transformer is two coils of insulated wire wound on a shared iron core. The primary coil connects to an AC supply, and the secondary coil connects to the load. The alternating current in the primary makes an alternating magnetic field, and the iron core guides almost all of that flux through the secondary as well. Because the flux in the secondary keeps changing, Faraday's law induces an alternating emf in it, at the same frequency as the supply. No current passes between the coils: energy crosses by the changing magnetic field alone. Phone chargers, doorbells, welders and the grey cans on utility poles all use this principle.

The turns ratio

In an ideal transformer every turn of both coils carries the same changing flux, so each turn has the same emf, \(\Delta\Phi/\Delta t\). The primary voltage is \(N_p\) times that and the secondary voltage \(N_s\) times it, so

\frac{V_s}{V_p} = \frac{N_s}{N_p}

A step-up transformer has more secondary turns and raises the voltage; a step-down transformer has fewer and lowers it. A secondary with one-tenth as many turns changes 120 V into 12 V. A transformer cannot work on steady DC: a constant current makes constant flux, so nothing is induced except brief pulses when the current is switched on or off.

Power in, power out

A transformer cannot create energy. An ideal one loses none, so the power into the primary equals the power out of the secondary:

V_pI_p = V_sI_s \quad\Rightarrow\quad \frac{I_s}{I_p} = \frac{N_p}{N_s}

Stepping the voltage up steps the current down by the same factor, and stepping it down steps the current up. Real transformers come close to this ideal. Large ones are over 99% efficient, and small ones somewhat less. The main losses are heating in the coils' resistance and heating in the core, much of it from eddy currents, which is why cores are laminated, as the eddy currents topic explained. Throughout this topic, voltages and currents are rms values.

Worked example: a phone charger

A charger's transformer takes 120 V from the wall and must give 6.00 V. Its primary has 800 turns, and the device draws 1.50 A from the secondary. Treat the transformer as ideal. Find the secondary turns and the primary current. 1. Turns: \(N_s = N_p(V_s/V_p) = 800 \times 6.00/120\), which is 40 turns. 2. Power out: \(V_sI_s = 6.00 \times 1.50 = 9.00\) W. 3. Primary current: \(I_p = 9.00/120 = 0.0750\) A. 4. Check with the turns ratio:

\frac{I_p}{I_s} = \frac{N_s}{N_p} = \frac{40}{800}

so \(I_p = 1.50/20 = 0.0750\) A. The high-voltage side carries the small current.

Worked example: stepping up for transmission

A power station generates 300 MW at 20.0 kV. Transformers raise this to 400 kV for a line of total resistance 5.00 Ω. Compare the line loss with and without the step-up. 1. Turns ratio: \(400/20.0 = 20\), so the secondary has 20 times the primary's turns. 2. Line current at 400 kV: \(I = P/V = 750\) A, and the loss is

I^2R = (750)^2(5.00) = 2.81 \times 10^6\ \text{W}

under 1% of the power sent. 3. At 20.0 kV the current would be 15,000 A, and \(I^2R\) would be \(1.13 \times 10^9\) W, more than the station produces: the power simply could not be delivered. 4. Check: 20 times the voltage gives 1/20 of the current and \(1/400\) of the loss.

From power station to outlet

Generators typically produce 10 to 25 kV. Step-up transformers at the station raise this to transmission voltages, commonly 115 kV to 765 kV in North America. Substations near towns step it down to distribution voltages of a few kilovolts to about 35 kV, carried along streets. A final transformer on a pole or a ground pad steps it down to 240 V for a home, centre-tapped to give two 120 V supplies: 120 V rms at 60 Hz for ordinary outlets and 240 V for ovens and dryers. At 60 Hz the current reverses direction 120 times a second.

The three-wire system

This card and the next explain how safety systems work; they are not safety advice, and electrical work belongs to qualified electricians. US outlets have three conductors. The live, or hot, wire carries the 120 V. The neutral wire is the normal return path and is connected to the earth at the building's main panel. The ground wire, the round third prong, connects an appliance's metal case to the earth. If worn insulation lets the live wire touch the case, a large current flows through the ground wire, and the breaker trips. Without that wire, the case could sit at 120 V until someone touched it. Appliances with two-prong plugs are usually double insulated, in plastic cases.

Ground fault circuit interrupters

A ground fault circuit interrupter, GFCI, uses induction to sense current going where it should not. The live and neutral wires both pass through a small iron ring, carrying currents in opposite directions. Normally the currents are equal, their fields cancel, and the ring's flux stays zero. If some current leaks to earth by another path, perhaps through a person, the currents differ, an alternating flux appears in the ring, and a sensing coil wound on it picks up an emf. The device then opens the circuit within a small fraction of a second when the difference reaches about 5 mA. It cannot detect a person touching both live and neutral, because that current returns through the neutral.

Worked example: why breakers do not protect people

A lamp draws 4.000 A on a 15 A circuit. A person touches a faulty live part, and a 20.0 kΩ path through their body and footwear leads to earth. 1. Leakage current: \(I = 120/(2.00 \times 10^4)\), which is 6.00 mA, well above the 1 mA that an earlier topic said can be felt. 2. The live wire now carries 4.006 A and the neutral 4.000 A. 3. The breaker sees 4.006 A, far below 15 A, and does nothing. 4. A GFCI sees a 6.00 mA difference, above its roughly 5 mA threshold, and trips. 5. Check: breakers guard wiring against overheating at tens of amperes; only a device that compares currents notices a few milliamperes.

Common mistakes to avoid

First, inverting the turns ratio: a step-down transformer has fewer secondary turns. Second, thinking a step-up transformer raises the power; it raises voltage and lowers current, and power out never exceeds power in. Third, expecting a transformer to work on steady DC. Fourth, mixing peak and rms values; mains figures such as 120 V are rms. Fifth, believing a circuit breaker protects a person from shock; it trips at far larger currents, and a GFCI is what responds to milliamperes.

Key takeaways

A transformer uses a changing flux in a shared core to induce an emf in a secondary coil. Ideally Vs/Vp = Ns/Np and VpIp = VsIs, so Is/Ip = Np/Ns; it needs AC, not steady DC. Raising the transmission voltage cuts the current and the I²R line loss, so the grid steps up to hundreds of kilovolts and back down to 120 V and 240 V at the home. The ground wire keeps metal cases at earth potential so a fault trips the breaker. A GFCI compares live and neutral currents and trips at about 5 mA.

Flashcards

Flashcard

Transformer

Two coils on a shared iron core that change an AC voltage

Energy crosses by the changing flux.

Test your understanding

Question 1 of 5

An ideal transformer's primary has 1200 turns and takes 120 V. How many secondary turns give 9.0 V?

Question 2 of 5

An ideal transformer steps 120 V up to 2400 V and delivers 0.50 A from its secondary. What current does the primary draw?

Question 3 of 5

A steady 12 V DC battery is connected to the primary of a transformer and left connected. What is the secondary's output?

Question 4 of 5

A GFCI measures 5.000 A in the live wire and 4.993 A in the neutral wire. What does this mean?

Question 5 of 5

What is the purpose of the ground wire connected to an appliance's metal case?